Reproducibility and inter-vendor variability of left ventricular deformation measurements by three-dimensional speckle-tracking echocardiography.

机译:三维斑点跟踪超声心动图测量左心室形变的可重复性和供应商间差异。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Myocardial deformation measurements using two-dimensional speckle-tracking echocardiography (STE) are known to vary among vendors. The intervendor agreement of three-dimensional (3D) deformation indices has not been studied. The goals of this study were to determine the intervendor agreement of 3D STE-based measurements of left ventricular (LV) deformation parameters to investigate the intrinsic variability of these measurements and identify the sources of intervendor differences. METHODS: Real-time full-volume images obtained in 30 subjects with normal LV systolic function using two vendors' equipment (V1 and V2) on the same day were analyzed by two independent observers using two software packages (S1 and S2). Agreement between three technique combinations (V1/S1, V2/S2, and V1/S2) and their intrinsic reproducibility (interobserver and intraobserver agreement) were assessed using intraclass correlation coefficients. Parameters of LV deformation included global longitudinal strain, twist, 3D displacement, and 3D strain and its radial, longitudinal, and circumferential components. RESULTS: For all three combinations, intertechnique agreement was poor (intraclass correlation coefficient < 0.4), always beyond the intrinsic variability. For all measured parameters, the intertechnique agreement was better when the same software package was used with images from different vendors (V2/S2 vs V1/S2) than when images from same vendor were analyzed using different software (V1/S2 vs V1/S1). CONCLUSIONS: Three-dimensional STE-derived LV deformation parameters are highly vendor dependent, and the discordance levels are beyond intrinsic measurement variability of any of the tested combinations of imaging equipment and analysis software. This intervendor discordance must be taken into account when interpreting 3D deformation data.
机译:背景:使用二维散斑跟踪超声心动图(STE)进行的心肌变形测量在不同厂商之间有所不同。尚未研究三维(3D)变形指数的供应商一致性。这项研究的目的是确定基于3D STE的左心室(LV)变形参数的测量结果之间的供应商一致性,以调查这些测量的内在变异性并确定供应商差异的来源。方法:由两名独立的观察者使用两个软件包(S1和S2)分析了当天使用两个供应商的设备(V1和V2)在30例具有正常LV收缩功能的受试者中获得的实时全体积图像。使用类内相关系数评估三种技术组合(V1 / S1,V2 / S2和V1 / S2)之间的一致性及其固有的可重复性(观察者间和观察者内一致性)。 LV变形的参数包括整体纵向应变,扭曲,3D位移和3D应变及其径向,纵向和圆周分量。结果:对于所有三种组合,技术间一致性差(类内相关系数<0.4),始终超出内在变异性。对于所有测得的参数,与使用不同软件(V1 / S2与V1 / S1)分析来自同一供应商的图像时,使用同一软件包处理来自不同供应商(V2 / S2与V1 / S2)的图像时,技术间协议更好。 )。结论:三维STE衍生的LV变形参数在很大程度上取决于供应商,并且不一致水平超出了成像设备和分析软件的任何测试组合的固有测量变异性。解释3D变形数据时,必须考虑到供应商之间的不一致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号