OBJECTIVES: During its German pilot phase, the EuroCMR (European Cardiovascular Magnetic Resonance) registry sought to evaluate indications, image quality, safety, and impact on patient management of routine CMR. BACKGROUND: CMR has a broad range of applications and is increasingly used in clinical practice. METHODS: This was a multicenter registry with consecutive enrollment of patients in 20 German centers. RESULTS: A total of 11,040 consecutive patients were enrolled. Eighty-eight percent of patients received gadolinium-based contrast agents. Twenty-one percent underwent adenosine perfusion, and 11% high-dose dobutamine-stress CMR. The most important indications were workup of myocarditis/cardiomyopathies (32%), risk stratification in suspected coronary artery disease/ischemia (31%), as well as assessment of viability (15%). Image quality was good in 90.1%, moderate in 8.1%, and inadequate in 1.8% of cases. Severe complications occurred in 0.05%, and were all associated with stress testing. No patient died during or due to CMR. In nearly two-thirds of patients, CMR findings impacted patient management. Importantly, in 16% of cases the final diagnosis based on CMR was different from the diagnosis before CMR, leading to a complete change in management. In more than 86% of cases, CMR was capable of satisfying all imaging needs so that no further imaging was required. CONCLUSIONS: CMR is frequently performed in clinical practice in many participating centers. The most important indications are workup of myocarditis/cardiomyopathies, risk stratification in suspected coronary artery disease/ischemia, and assessment of viability. CMR imaging as used in the centers of the pilot registry is a safe procedure, has diagnostic image quality in 98% of cases, and its results have strong impact on patient management.
机译:目标:在其德国试点阶段,EuroCMR(欧洲心血管磁共振)注册中心试图评估适应症,图像质量,安全性以及对常规CMR患者管理的影响。背景:CMR具有广泛的应用范围,并且在临床实践中越来越多地使用。方法:这是一个多中心注册表,在20个德国中心中连续招募了患者。结果:共纳入11040例连续患者。 88%的患者接受了基于g的造影剂。 21%的人接受腺苷灌注,11%的高剂量多巴酚丁胺应激CMR。最重要的指征是心肌炎/心肌病的检查(32%),可疑冠状动脉疾病/缺血的危险分层(31%)以及生存力评估(15%)。在90.1%的情况下,图像质量良好;在8.1%的情况下,图像质量不佳。严重并发症的发生率为0.05%,并且都与压力测试有关。没有患者在CMR期间或因CMR死亡。在近三分之二的患者中,CMR结果影响了患者管理。重要的是,在16%的病例中,基于CMR的最终诊断与CMR之前的诊断不同,从而导致管理上的彻底改变。在超过86%的情况下,CMR能够满足所有成像需求,因此不需要进一步成像。结论:许多参与中心的临床实践中经常进行CMR。最重要的适应症是心肌炎/心肌病的检查,可疑冠状动脉疾病/局部缺血的危险分层以及生存能力评估。飞行员登记中心使用的CMR成像是一种安全的程序,在98%的病例中具有诊断图像质量,其结果对患者管理有很大影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号