Objectives: This was a phase II trial to assess flurpiridaz F 18 for safety and compare its diagnostic performance for positron emission tomography (PET) myocardial perfusion imaging (MPI) with Tc-99m single-photon emission computed tomography (SPECT) MPI with regard to image quality, interpretative certainty, defect magnitude, and detection of coronary artery disease (CAD) (??50% stenosis) on invasive coronary angiography (ICA). Background: In pre-clinical and phase I studies, flurpiridaz F 18 has shown characteristics of an essentially ideal MPI tracer. Methods: One hundred forty-three patients from 21 centers underwent rest-stress PET and Tc-99m SPECT MPI. Eighty-six patients underwent ICA, and 39 had low-likelihood of CAD. Images were scored by 3 independent, blinded readers. Results: A higher percentage of images were rated as excellent/good on PET versus SPECT on stress (99.2% vs. 88.5%, p < 0.01) and rest (96.9% vs. 66.4, p < 0.01) images. Diagnostic certainty of interpretation (percentage of cases with definitely abnormalormal interpretation) was higher for PET versus SPECT (90.8% vs. 70.9%, p < 0.01). In 86 patients who underwent ICA, sensitivity of PET was higher than SPECT (78.8% vs. 61.5%, respectively, p = 0.02). Specificity was not significantly different (PET: 76.5% vs. SPECT: 73.5%). Receiver-operating characteristic curve area was 0.82 ?? 0.05 for PET and 0.70 ?? 0.06 for SPECT (p = 0.04). Normalcy rate was 89.7% with PET and 97.4% with SPECT (p = NS). In patients with CAD on ICA, the magnitude of reversible defects was greater with PET than SPECT (p = 0.008). Extensive safety assessment revealed that flurpiridaz F 18 was safe in this cohort. Conclusions: In this phase 2 trial, PET MPI with flurpiridaz F 18 was safe and superior to SPECT MPI for image quality, interpretative certainty, and overall CAD diagnosis. ? 2013 American College of Cardiology Foundation.
机译:目的:这是一项II期试验,旨在评估氟吡哌唑F 18的安全性,并比较其对Tc-99m单光子发射计算机断层扫描(SPECT)MPI的正电子发射断层扫描(PET)心肌灌注成像(MPI)的诊断性能图像质量,解释性确定性,缺陷严重程度以及在有创冠状动脉造影(ICA)上检测冠状动脉疾病(CAD)(狭窄程度为50%)。背景:在临床前和I期研究中,氟哌啶酮F 18已显示出本质上理想的MPI示踪剂的特征。方法:来自21个中心的143例患者接受了静息PET和Tc-99m SPECT MPI。 86例患者接受了ICA,其中39例患者的CAD可能性较低。图片由3个独立的盲人读者评分。结果:在PET图像上,相对于受压力(SPECT)的SPECT(99.2%vs. 88.5%,p <0.01)和静止图像(96.9%vs. 66.4,p <0.01)的图像百分比更高,被评为“优秀/良好”。与SPECT相比,PET的解释诊断肯定性(绝对解释为异常/正常的病例百分比)更高(90.8%对70.9%,p <0.01)。在接受ICA的86例患者中,PET的敏感性高于SPECT(分别为78.8%和61.5%,p = 0.02)。特异性无显着差异(PET:76.5%与SPECT:73.5%)。接收者操作特性曲线面积为0.82 ?? PET为0.05,0.70 ?? SPECT为0.06(p = 0.04)。 PET和SPECT的正常率分别为89.7%和97.4%(p = NS)。在ICA上进行CAD的患者中,PET可逆缺陷的幅度大于SPECT(p = 0.008)。广泛的安全性评估显示,氟哌啶酮F 18在该队列中是安全的。结论:在该2期试验中,氟吡哌酮F 18的PET MPI在图像质量,解释确定性和总体CAD诊断方面优于SPECT MPI。 ? 2013美国心脏病学会基金会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号