摘要

A method to enhance the signal intensity and signal-to-noise of several alkyl methylphosphonic acids in negative electrospray ionization liquid chromatography tandem mass spectrometry (ESI LC-MS/MS) is presented. This class of compound represents the initial metabolites and environmental degradants of the nerve agents: VX, rVX (Russian VX), GB (Sarin), GF (Cyclosarin), and GD (Soman). Compared with the post-column addition of the mobile phase, the post-column addition of aprotic solvents and longer chain alcohols enhance the signal intensity and signal-to-noise ratio (S/N) of the chromatographic peaks by factors of up to 60 and 19, respectively. The post-column addition of water, methanol, and ethanol resulted in little or no relative signal enhancement. It is proposed that the post-column addition of these solvents do not result in the same enhancements due to stabilization of analyte solvation through hydrogen bonding.
机译:提出了一种在负电喷雾电离液相色谱串联质谱法(ESI LC-MS / MS)中增强几种烷基甲基膦酸的信号强度和信噪比的方法。这类化合物代表神经毒剂的初始代谢产物和环境降解物:VX,rVX(俄罗斯VX),GB(沙林),GF(环沙林)和GD(苏曼)。与柱后添加流动相相比,柱后添加非质子溶剂和较长链醇可将色谱峰的信号强度和信噪比(S / N)提高多达60倍和19。柱后添加水,甲醇和乙醇导致相对信号增强很少或没有。有人提出,由于通过氢键稳定分析物溶剂化,这些溶剂的柱后添加不会导致相同的增强。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号