The capabilities of a portable mass spectrometer for real-time monitoring of trace levels of benzene, toluene, and ethylbenzene in air are illustrated. An atmospheric pressure interface was built to implement atmospheric pressure chemical ionization for direct analysis of gas-phase samples on a previously described miniature mass spectrometer (Gao et al. Anal. Chem. 2006, 78, 5994–6002). Linear dynamic ranges, limits of detection and other analytical figures of merit were evaluated: for benzene, a limit of detection of 0.2 parts-per-billion was achieved for air samples without any sample preconcentration. The corresponding limits of detection for toluene and ethylbenzene were 0.5 parts-per-billion and 0.7 parts-per-billion, respectively. These detection limits are well below the compounds’ permissible exposure levels, even in the presence of added complex mixtures of organics at levels exceeding the parts-per-million level. The linear dynamic ranges of benzene, toluene, and ethylbenzene are limited to approximately two orders of magnitude by saturation of the detection electronics.
机译:说明了便携式质谱仪实时监测空气中痕量苯,甲苯和乙苯的功能。建立了一个大气压接口以实现大气压化学电离,以便在先前描述的微型质谱仪上直接分析气相样品(Gao等人,Anal。Chem。2006,78,5994–6002)。评估了线性动态范围,检出限和其他分析品质因数:对于苯,没有任何样品预浓缩的空气样品检出限为0.2十亿分之一。甲苯和乙苯的相应检出限分别为十亿分之0.5和十亿分之0.7。即使存在超过百万分之几的复杂有机混合物,这些检测限也远低于化合物的允许暴露水平。苯,甲苯和乙苯的线性动态范围由于检测电子器件的饱和而限制在大约两个数量级。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号