首页> 外文期刊>Journal of the American Society for Mass Spectrometry >Assessment of resolution parameters for CID-based shotgun proteomic experiments on the LTQ-orbitrap mass spectrometer
【24h】

Assessment of resolution parameters for CID-based shotgun proteomic experiments on the LTQ-orbitrap mass spectrometer

机译:LTQ-orbitrap质谱仪上基于CID的shot弹枪蛋白质组实验的分辨率参数评估

获取原文
获取原文并翻译 | 示例
           

摘要

Shotgun proteomics has been used extensively for characterization of a number of proteomes. High-resolution Fourier transform mass spectrometry (FTMS) has emerged as a powerful tool owing to its high mass accuracy and resolving power. One of its major limitations, however, is that the confidence level of peptide identification and sensitivity cannot be maximized simultaneously. Although it is generally assumed that higher resolution is better for peptide identifications, the precise effect of varying resolution as a parameter on peptide identification has not yet been systematically evaluated. We used the Escherichia coli proteome and a standard 48 protein mix to study the effect of different resolution parameters on peptide identifications in the setting of a shotgun proteomics experiment on an LTQ-Orbitrap mass spectrometer. We observed a higher number of peptide-spectrum matches (PSMs) whenever the MS scan was carried out by FT and the MS/MS in the ion-trap (IT) with the maximum PSMs obtained at an MS resolution of 30,000. In contrast, when samples were analyzed by FT for both MS and MS/MS, the number of PSMs was significantly lower (~40% compared with FT-IT experiments) with the maximum PSMs obtained when both the MS and MS/MS resolution were set to 15,000. Thus, a 15K-15K resolution setting may provide the best compromise for studies where both speed and accuracy such as high-throughput post-translational analysis and de novo sequencing are important. We hope that our study will allow researchers to choose between different resolution parameters to achieve their desired results from proteomic analyses.
机译:gun弹枪蛋白质组学已广泛用于表征许多蛋白质组。高分辨率傅里叶变换质谱(FTMS)由于其高质量的准确性和分辨能力而成为一种强大的工具。然而,其主要限制之一是不能同时最大化肽鉴定和置信度的置信度。尽管通常认为较高的分辨率对肽的鉴定更好,但尚未系统地评估改变分辨率作为肽鉴定的参数的精确效果。我们使用大肠杆菌蛋白质组和标准的48种蛋白质混合物来研究在LTQ-Orbitrap质谱仪上进行shot弹枪蛋白质组学实验时,不同分辨率参数对肽鉴定的影响。每当FT进行MS扫描和离子阱(IT)中的MS / MS进行MS扫描时,我们观察到更高数量的肽谱匹配(PSM),且MS分辨率为30,000时可获得最大PSM。相反,当通过FT分析MS和MS / MS的样品时,PSM的数量显着降低(与FT-IT实验相比约为40%),而当MS和MS / MS分辨率均达到设置为15,000。因此,对于高速度和准确性(例如高通量翻译后分析和从头测序)均很重要的研究,15K-15K分辨率设置可能会提供最佳折中方案。我们希望我们的研究将允许研究人员在不同的分辨率参数之间进行选择,以从蛋白质组学分析中获得所需的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号