...
首页> 外文期刊>Journal of strength and conditioning research >Reliability, minimal detectable change, and normative values for tests of upper extremity function and power.
【24h】

Reliability, minimal detectable change, and normative values for tests of upper extremity function and power.

机译:可靠性,最小的可检测变化以及用于测试上肢功能和力量的标准值。

获取原文
获取原文并翻译 | 示例

摘要

The purpose of this study was to examine the test-retest reliability, minimal detectable change (MDC), and determine normative values of 3 upper extremity (UE) tests of function and power. One hundred eighty participants, men (n = 69) and women (n = 111), were tested on 3 UE strength and power maneuvers in a multicenter study to determine baseline normative values. Forty-six subjects returned for a second day of testing within 5 days of the initial assessment for the reliability component of the investigation. Explosive power was assessed via a seated shot-put test for the dominant and nondominant arms. Relationships between the dominant and nondominant arms were also analyzed. A push-up and modified pull-up were performed to measure the amount of work performed in short (15-second) bursts of activity. The relationship between the push-up and modified pull-up was also determined. Analysis showed test-retest reliability for the modified pull-up, timed push-up, dominant single-arm seated shot-put tests, and nondominant single-arm seated shot-put tests to be intraclass correlation coefficient(3,1) 0.958, 0.989, 0.988, and 0.971, respectively. The MDC for both the push-up and modified pull-up was 2 repetitions. The MDCs for the shot put with the dominant arm and the nondominant arm were 17 and 18 in., respectively. The result of this study indicates that these field tests possess excellent reliability. Normative values have been identified, which require further validation. These tests demonstrate a practical and effective method to measure upper extremity functional power.
机译:这项研究的目的是检查重测的可靠性,最小可检测变化(MDC),并确定3个功能和力量的上肢(UE)测试的规范值。在一项多中心研究中,通过3种UE力量和力量测试对180名参与者(男性(n = 69)和女性(n = 111))进行了测试,以确定基线标准值。在调查的可靠性部分的初始评估后的5天内,四十六名受试者返回进行了第二天的测试。通过对主要和非主要武器的坐姿射击测试来评估其爆炸力。还分析了支配臂和非支配臂之间的关系。进行俯卧撑和改良的上拉,以测量在短时间(15秒)的活动中完成的工作量。还确定了上拉和改良上拉之间的关系。分析显示,改良的上拉,定时俯卧撑,优势单臂坐式铅球测试和非优势单臂坐式铅球测试的重测信度为组内相关系数(3,1)0.958,分别为0.989、0.988和0.971。上拉和修改上拉的MDC为2次重复。带有优势臂和非优势臂的铅球的MDC分别为17英寸和18英寸。这项研究的结果表明,这些现场测试具有出色的可靠性。已经确定了规范值,需要进一步验证。这些测试证明了一种测量上肢功能能力的实用有效的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号