...
首页> 外文期刊>Journal of strength and conditioning research >Test-retest reliability of barbell velocity during the free-weight bench-press exercise.
【24h】

Test-retest reliability of barbell velocity during the free-weight bench-press exercise.

机译:自由重量卧推练习中杠铃速度的重测可靠性。

获取原文
获取原文并翻译 | 示例

摘要

The purpose of this study was to calculate test-retest reliability statistics for peak barbell velocity during the free-weight bench-press exercise for loads corresponding to 10-90% of the 1-repetition maximum (1RM). Twenty-one healthy, resistance-trained men (mean +/- SD age = 23.5 +/- 2.7 years; body mass = 90.5 +/- 14.6 kg; 1RM bench press = 125.4 +/- 18.4 kg) volunteered for this study. A minimum of 48 hours after a maximal strength testing and familiarization session, the subjects performed single repetitions of the free-weight bench-press exercise at each tenth percentile (10-90%) of the 1RM on 2 separate occasions. For each repetition, the subjects were instructed to press the barbell as rapidly as possible, and peak barbell velocity was measured with a Tendo Weightlifting Analyzer. The test-retest intraclass correlation coefficients (model 2,1) and corresponding standard errors of measurement (expressed as percentages of the mean barbell velocity values) were 0.717 (4.2%), 0.572 (5.0%), 0.805 (3.1%), 0.669 (4.7%), 0.790 (4.6%), 0.785 (4.8%), 0.811 (5.8%), 0.714 (10.3%), and 0.594 (12.6%) for the weights corresponding to 10-90% 1RM. There were no mean differences between the barbell velocity values from trials 1 and 2. These results indicated moderate to high test-retest reliability for barbell velocity from 10 to 70% 1RM but decreased consistency at 80 and 90% 1RM. When examining barbell velocity during the free-weight bench-press exercise, greater measurement error must be overcome at 80 and 90% 1RM to be confident that an observed change is meaningful.
机译:这项研究的目的是计算自由重量卧推练习中杠铃速度峰值的重测信度统计数据,该负重对应于1次重复最大值(1RM)的10-90%。 21名健康且经过抗性训练的男性(平均+/- SD年龄= 23.5 +/- 2.7岁;体重= 90.5 +/- 14.6 kg; 1RM卧推= 125.4 +/- 18.4 kg)自愿参加这项研究。在进行最大强度测试和熟悉训练后至少48小时内,受试者分别在1RM的每十分之一(10-90%)进行两次自由重量卧推练习的重复。对于每次重复,都指示受试者尽快按杠铃,并使用Tendo举重分析仪测量杠铃峰值速度。重测组内相关系数(模型2,1)和相应的标准测量误差(表示为平均杠铃速度值的百分比)分别为0.717(4.2%),0.572(5.0%),0.805(3.1%),0.669 (4.7%),0.790(4.6%),0.785(4.8%),0.811(5.8%),0.714(10.3%)和0.594(12.6%)(对应于10-90%1RM)。试验1和2的杠铃速度值之间没有均值差异。这些结果表明,杠铃速度从10%到70%1RM适度到较高的重测可靠性,但在80%和90%1RM时一致性降低。在自由举重卧推练习中检查杠铃速度时,必须克服80%和90%1RM时更大的测量误差,以确保观察到的变化有意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号