...
首页> 外文期刊>Journal of spinal disorders & techniques. >Comparison of novel ultra-high molecular weight polyethylene tape versus conventional metal wire for sublaminar segmental fixation in the treatment of adolescent idiopathic scoliosis.
【24h】

Comparison of novel ultra-high molecular weight polyethylene tape versus conventional metal wire for sublaminar segmental fixation in the treatment of adolescent idiopathic scoliosis.

机译:新型超高分子量聚乙烯胶带与常规金属线用于层状节段固定治疗青少年特发性脊柱侧弯的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY DESIGN: Retrospective study. OBJECTIVES: To compare the surgical outcomes of posterior translational correction and fusion using hybrid instrumentation systems with either sublaminar Nesplon tape or sublaminar metal wire to treat adolescent idiopathic scoliosis (AIS). SUMMARY OF BACKGROUND DATA: Nesplon tape, which consists of a thread of ultra-high molecular weight polyethylene fibers, has advantages over metal wire: (1) its soft and flexible properties avoid neural damage and (2) its flat configuration avoids focal distribution of the stresses to lamina; however, the efficacy of Nesplon tape in the correction of spinal deformity is as yet, still unclear. METHODS: Thirty AIS patients at a single institution underwent posterior correction and fusion using hybrid instrumentation containing hook, pedicle screw, and either sublaminar polyethylene taping (15) or sublaminar metal wiring (15). Patients were evaluated preoperatively, immediately after surgery, and at a 2-year follow-up according to the radiographic changes in curve correction, operating time, intraoperative blood loss, complications, and the Scoliosis Research Society patient questionnaire (SRS-24) score. RESULTS: The average correction rate was 63.0% in the Nesplon tape group and 59.9% in the metal wire group immediately after surgery (P = 0.62). Fusion was obtained in all the patients without significant correction loss in both groups. There was no significant difference in operative time, intraoperative blood loss, and postoperative SRS-24 scores between the 2 groups. Complications were superficial skin infection in a single patient in the Nesplon tape group, and transient sensory disturbance in 1 patient and temporal superior mesenteric artery syndrome in another patient in the metal wire group. CONCLUSIONS: The efficacy of Nesplon tape in correction of deformity is equivalent to that of metal wire, and fusion was completed without significant correction loss. The soft and flexible properties and flat configuration of Nesplon tape make this a safe application for the treatment of AIS with bone fragility or with the fusion areas containing the spinal cord.
机译:研究设计:回顾性研究。目的:比较混合后置系统与椎板下Nesplon胶带或椎板下金属线治疗青少年特发性脊柱侧凸(AIS)的后平移校正和融合的手术效果。背景数据摘要:由超高分子量聚乙烯纤维制成的Nesplon胶带具有优于金属丝的优点:(1)柔软而柔软的特性避免了神经损伤;(2)扁平的形状避免了金属丝的局部分布对椎板的应力;但是,Nesplon胶带在矫正脊柱畸形中的功效尚不清楚。方法:在单个机构中对30名AIS患者进行后路矫正和融合,方法是使用混合器械,包括钩子,椎弓根螺钉和层下聚乙烯带(15)或层下金属线(15)。术前,手术后立即对患者进行评估,并根据曲线校正,手术时间,术中失血量,并发症和脊柱侧弯研究协会患者问卷(SRS-24)评分的影像学变化对患者进行2年的随访。结果:手术后即刻,Nesplon胶带组的平均校正率为63.0%,金属线材组的平均校正率为59.9%(P = 0.62)。在所有患者中均获得融合,两组均无明显矫正损失。两组之间的手术时间,术中失血量和术后SRS-24评分均无显着差异。并发症是Nesplon胶带组中的一名患者发生浅表皮肤感染,金属线组中的另一名患者出现短暂的感觉障碍,另一名患者出现颞上肠系膜上动脉综合征。结论:Nesplon胶带在矫正畸形方面的功效与金属丝相当,并且完成融合后没有明显的矫正损失。 Nesplon胶带的柔软,柔软的特性和平坦的结构使其成为治疗具有骨脆性或包含脊髓的融合区域的AIS的安全应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号