首页> 外文期刊>Journal of separation science. >Efficient sample clean-up and online preconcentration for sensitive determination of melamine in milk samples by capillary electrophoresis with contactless conductivity detection
【24h】

Efficient sample clean-up and online preconcentration for sensitive determination of melamine in milk samples by capillary electrophoresis with contactless conductivity detection

机译:高效的样品净化和在线预浓缩,可通过毛细管电泳和非接触电导检测灵敏地测定牛奶样品中的三聚氰胺

获取原文
获取原文并翻译 | 示例
           

摘要

Based on an efficient sample clean-up and field-amplified sample injection online preconcentration technique in capillary electrophoresis with contactless conductivity detection, a new analytical method for the sensitive determination of melamine in milk samples was established. In order to remove the complexmatrix interference, which resulted in a serious problem during field-amplified sample injection, liquid-liquid extraction was utilized. As a result, liquid-liquid extraction provides excellent sample clean-up efficiency when ethyl acetate was used as organic extraction by adjusting the pH of the sample solution to 9.5. Both inorganic salts and biologicalmacromolecules are effectively removed by liquid-liquid extraction. The sample clean-up procedure, capillary electrophoresis separation parameters and field-amplified sample injection conditions are discussed in detail. The capillary electrophoresis separation was achieved within 5 min under the following conditions: an uncoated fused-silica capillary, 12 mM HAc + 10 mM NaAc (pH = 4.6) as running buffer, separation voltage of +13 kV, electrokinetic injection of +12 kV × 10 s. Preliminary validation of the method performance with spiked melamine provided recoveries >90%, with limits of detection and quantification of 0.015 and 0.050 mg/kg, respectively. The relative standard deviations of intra- and inter-day were below 6%. This newly developed method is sensitive and cost effective, therefore, suitable for screening of melamine contamination in milk products.
机译:基于高效的毛细管电泳无接触电导检测中的样品净化和现场扩增在线进样富集技术,建立了一种灵敏测定牛奶样品中三聚氰胺的新分析方法。为了消除复杂的基质干扰,这在现场放大的样品注入过程中造成了严重的问题,因此采用了液-液萃取。结果,当将乙酸乙酯用作有机萃取物时,通过将样品溶液的pH值调节到9.5,液-液萃取可提供出色的样品净化效率。通过液-液萃取有效地去除了无机盐和生物大分子。详细讨论了样品净化程序,毛细管电泳分离参数和现场放大的样品进样条件。在以下条件下,在5分钟内完成了毛细管电泳分离:未涂覆的熔融石英毛细管,作为运行缓冲液的12 mM HAc + 10 mM NaAc(pH = 4.6),分离电压+13 kV,电动注入+12 kV ×10秒掺加三聚氰胺的方法性能的初步验证提供了> 90%的回收率,检出限和定量限分别为0.015和0.050 mg / kg。日内和日间的相对标准偏差在6%以下。这种新开发的方法灵敏且具有成本效益,因此适用于筛查奶制品中三聚氰胺的污染。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号