A liquid chromatography with tandem mass spectrometry method was developed for the simultaneous screening of 34 drugs and poisons in forensic cases. Blood (0.5 mL, diluted 1:1 with water) or 1.0 mL of urine was purified by solid-phase extraction. Gastric contents (diluted 1:1 with water) were treated with acetonitrile, centrifuged, and supernatant injected. Detection was achieved using a Waters Alliance 2695/Quattro Premier XE liquid chromatography tandem mass spectrometry system equipped with electrospray ionization, operated in the multiple reaction monitoring modes. The method was validated for accuracy, precision, linearity, and recovery. The absolute recovery of drugs and toxic compounds in blood was greater than 51% with the limit of detection in the range of 0.02-20 ng/mL. The absolute recovery of drugs and toxic compounds in urine was greater than 61% with limit of detection in the range of 0.01-10 ng/mL. The matrix effect of drugs and toxic compounds in urine was 65-117% and 67-121% in blood. The limit of detection of drugs and toxic compounds in gastric content samples were in the range of 0.05-20 ng/mL. This method was applied to the routine analysis of drugs and toxic compounds in postmortem blood, urine, and gastric content samples. The method was applied to actual forensic cases with examples given.
机译:开发了一种液相色谱-串联质谱法,用于同时筛查法医案件中的34种药物和毒物。通过固相萃取纯化血液(0.5 mL,用水1:1稀释)或1.0 mL尿液。胃内容物(用水1:1稀释)用乙腈处理,离心并注入上清液。使用配备有电喷雾电离的Waters Alliance 2695 / Quattro Premier XE液相色谱串联质谱系统完成检测,该系统在多种反应监测模式下运行。该方法的准确性,精密度,线性和回收率均得到验证。血液中药物和有毒化合物的绝对回收率大于51%,检出限为0.02-20 ng / mL。尿液中药物和有毒化合物的绝对回收率大于61%,检出限为0.01-10 ng / mL。尿液中药物和有毒化合物的基质效应在血液中为65-117%和67-121%。胃内容物样品中的药物和有毒化合物的检出限为0.05-20 ng / mL。该方法用于常规分析死后血液,尿液和胃内容物样品中的药物和有毒化合物。结合实例,将该方法应用于实际法医案件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号