首页> 外文期刊>Journal of separation science. >Simultaneous determination of peroxydisulfate and conventional inorganic anions by ion chromatography with the column-switching technique
【24h】

Simultaneous determination of peroxydisulfate and conventional inorganic anions by ion chromatography with the column-switching technique

机译:柱切换技术通过离子色谱法同时测定过氧二硫酸盐和常规无机阴离子

获取原文
获取原文并翻译 | 示例
           

摘要

The application of ion chromatography with the column-switching technique for the simultaneous analysis of peroxydisulfate and conventional inorganic anions in a single run is described. With this method, conventional inorganic anions were separated by consecutive elution through both the guard column and separation column, but peroxydisulfate that only passed through the guard column had a good peak shape and short retention time. A series of standard solutions consisting of target anions of various concentrations from 0.01 to 75 mg/L were analyzed, with a correlation coefficient (r) ≥ 0.9990. The limits of detection were in the range of 0.49-9.84 μg/L based on the S/N of 3 and a 25 μL injection volume. RSDs for retention time, peak area, and peak height were all <1.77%. A spiking study was performed with satisfactory recoveries between 97.6 and 103.4% for all anions. The quantitative determination of peroxydisulfate and conventional inorganic anions in surface waters was accomplished within 18 min by this column-switching technique.
机译:描述了使用色谱柱切换技术的离子色谱在一次运行中同时分析过氧二硫酸盐和常规无机阴离子的应用。使用这种方法,可以通过保护柱和分离柱的连续洗脱来分离常规的无机阴离子,但是仅通过保护柱的过氧二硫酸盐具有良好的峰形和较短的保留时间。分析了一系列标准溶液,这些溶液由浓度范围为0.01至75 mg / L的目标阴离子组成,相关系数(r)≥0.9990。基于3的S / N和25μL的进样量,检测限在0.49-9.84μg/ L的范围内。保留时间,峰面积和峰高的RSD均<1.77%。进行了一项加标研究,所有阴离子的回收率均在97.6%至103.4%之间。通过这种柱切换技术,可以在18分钟内完成地表水中过氧二硫酸盐和常规无机阴离子的定量测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号