首页> 外文期刊>Journal of separation science. >Development and application of chemometric-assisted dispersive liquid-liquid microextraction for the determination of suspected fragrance allergens in water samples
【24h】

Development and application of chemometric-assisted dispersive liquid-liquid microextraction for the determination of suspected fragrance allergens in water samples

机译:化学计量辅助分散液-液微萃取技术在水样中可疑香料过敏原测定中的开发与应用

获取原文
获取原文并翻译 | 示例
           

摘要

A simple and green method based on dispersive liquid-liquid microextraction, mated to chemometrics and followed by mass spectrometric detection for the determination of suspected fragrance allergens in water samples is developed and assessed in this work. Volume of extraction and disperser solvent, pH, ionic strength, extraction time, sample volume, as well as centrifugation time were initially optimized in a fractional factorial design. The obtained significant factors were optimized by using a central composite design and the quadratic model between the dependent and the independent variables was built. The obtained optimal conditions were: aqueous sample of 3.8 mL, 100 μL chloroform, 1.40 mL acetone, 4 min centrifugation time, natural pH containing 5% (w/v) NaCl, and centrifugation speed 4000 rpm. Method proved to be linear over a wide range of concentration for all analytes with R ~2 between 0.9807 and 0.9959. The repeatability and reproducibility of the proposed method, expressed as relative standard deviation, varied between 3-13% and 4-16%, respectively. The limits of detection ranged from 0.007 to 1.0 μg L ~(-1). The recommended method was applied to water samples including baby bath as well as swimming pool water samples and was compared with a previously reported method.
机译:在这项工作中,开发并评估了一种简单的绿色方法,该方法基于分散液-液微萃取,与化学计量学相配,然后进行质谱检测,以确定水中的可疑香料过敏原。提取和分散溶剂的体积,pH,离子强度,提取时间,样品量以及离心时间最初是在分数分解设计中优化的。通过使用中央复合设计优化获得的显着因子,并建立因变量和自变量之间的二次模型。获得的最佳条件是:3.8 mL的水样,100μL的氯仿,1.40 mL的丙酮,4分钟的离心时间,含有5%(w / v)NaCl的自然pH和4000 rpm的离心速度。对于R〜2在0.9807至0.9959之间的所有分析物,该方法在宽浓度范围内均呈线性关系。以相对标准偏差表示的方法的重复性和重现性分别在3-13%和4-16%之间变化。检出限范围为0.007至1.0μgL〜(-1)。推荐的方法应用于包括婴儿洗澡在内的水样以及游泳池水样,并与先前报道的方法进行了比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号