The on-site laboratory (OSL) at Rokkasho Reprocessing Plant (RRP) is jointly operated by the Japanese authority Nuclear Material Control Centre and the International Atomic Energy Agency (IAEA) and provides, together with the Nuclear Material Laboratory (NML) at Seibersdorf, analytical services to the IAEA's inspectorate. OSL deals with a variety of samples typical to a reprocessing plant including pure product solutions of uranium and plutonium but also mixed U/Pu solutions originating from various stages of the chemical process. For a significant proportion of the samples, the requirement on measurement accuracy and precision from the Inspectorate makes the use of thermal ionization mass spectrometry (TIMS) indispensible. Until recently, all samples intended for TIMS had to undergo time-consuming U/Pu separation before isotope dilution measurement. The need for rapid reporting of analytical results for certain safeguards samples evoked the idea of performing TIMS measurements without prior U/Pu separation for mixed U/Pu products as they are obtained from the PUREX process at RRP. For this purpose, a systematic study was initiated to probe the figure of merits and limitations of conducting TIMS analyses on mixed U/Pu samples and, in particular, whether the accuracy and precision of the main ratios of interest, n(~235U)(~(238)U) and n(~240Pu)(~239Pu), are influenced by the presence of larger amounts of the other element. A series of synthetic mixtures with U/Pu ratios ranging from 1:10 up to 100:1 were prepared and measured in both laboratories-OSL and NML-using ThermoFisher TRITON multi-collector TIMS instruments. For the n(~235U)/ ~(238)U) ratio, interference due to ~(238)Pu was observed which can be significant depending on the U/Pu ratio and the Pu abundance. However, for the n(~(240)Pu)(~(239)Pu) ratio, which is of premier importance for safeguarding RRP, no significant interference arising from the concomitant U was detected independently of enrichment. Even in samples with an excess of U (U/Pu ratio of 100:1), compliance with International Target Values (ITV2010) was demonstrated for n(~240Pu)(~239Pu) results with a relative difference to certified not exceeding 0.01 %.
机译:六所町后处理厂(RRP)的现场实验室(OSL)由日本权威核材料控制中心和国际原子能机构(IAEA)共同运营,并与塞伯斯多夫的核材料实验室(NML)一起提供,向国际原子能机构视察局提供分析服务。 OSL处理后处理工厂的各种典型样品,包括铀和p的纯产品溶液,以及来自化学过程各个阶段的混合U / Pu溶液。对于很大一部分样品,检查局对测量精度和精确度的要求使得使用热电离质谱法(TIMS)必不可少。直到最近,所有用于TIMS的样品在进行同位素稀释测量之前都必须经历费时的U / Pu分离。快速报告某些保障措施样品的分析结果的需求引发了进行TIMS测量而无需事先对混合U / Pu产品进行U / Pu分离的想法,因为它们是从RRP的PUREX工艺获得的。为此目的,开始了系统的研究,以探讨对混合的U / Pu样品进行TIMS分析的优缺点图,尤其是主要感兴趣比率n(〜235U)/的准确性和精确性。 n(〜(238)U)和n(〜240Pu)/ n(〜239Pu)受大量其他元素的存在影响。使用ThermoFisher TRITON多收集器TIMS仪器在OSL和NML实验室中制备并测量了一系列U / Pu比为1:10至100:1的合成混合物。对于n(〜235U)/〜(238U)比,观察到〜(238)Pu引起的干扰,根据U / Pu比和Pu的丰度,干扰可能很明显。但是,对于n(〜(240)Pu)/ n(〜(239)Pu)比率(对于保护RRP至关重要),没有检测到伴随富集而产生的显着干扰,而与富集无关。即使样品中的U(U / Pu比为100:1)过量,也证明其n(〜240Pu)/ n(〜239Pu)结果符合国际目标值(ITV2010),与认证的相对差异不超过0.01%。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号