首页> 外文期刊>Journal of Radioanalytical and Nuclear Chemistry: An International Journal Dealing with All Aspects and Applications of Nuclear Chemistry >New SRDN-3 probes with a semi-conductor detector for measuring radon activity concentration in underground spaces
【24h】

New SRDN-3 probes with a semi-conductor detector for measuring radon activity concentration in underground spaces

机译:带有半导体探测器的新型SRDN-3探头,用于测量地下空间中的activity活度浓度

获取原文
获取原文并翻译 | 示例
           

摘要

The article presents new Polish probes SRDN-3, developed at the Institute of Nuclear Chemistry and Technology in Warsaw, equipped with a semi-conductor detector used for continuous measurements of ~(222)Rn activity concentration. Due to a relatively high lower detection limit, the device is dedicated for use in underground spaces-caves, adits, mines, tourist routes in strongholds, pyramids, etc. Its structure allows for difficult conditions in which the device is transported to the measurement site, as well as hard operating conditions caused chiefly by large ambient relative humidity, reaching up to 100%. The authors present calibration results of these appliances, as well as the results of their work in a cave and an adit in the Sudetes (SW Poland). After almost 2 years of working in difficult conditions, the probes displayed high reliability. No defects of the semi-conductor detectors or the electronics were observed, which ensured problem-free communication of the probe-programmer-PC set. Thanks to this, the authors have a 2 year stock of data, recorded hourly by five probes, at their disposal. The only element that did not withstand the test of extreme operating conditions was one of the combined relative humidity and temperature sensors. No powering problems were observed either, and the batteries were replaced once a year, before the winter season. Also the programmer functioned faultlessly, enabling data transmission to a PC, which, being much more sensitive to operating conditions, had been placed away from the site of probe exposure. After using more sensitive temperature, relative humidity and pressure sensors, SRDN-3 probes will certainly prove an excellent tool for microclimate measurements (including measurement of air-atmosphere exchange) in caves and other underground sites. Even nowadays they are already a satisfactory tool for monitoring ~(222)Rn concentration in underground spaces.
机译:本文介绍了由华沙核化学技术研究所开发的新型波兰探针SRDN-3,该探针配备了用于连续测量〜(222)Rn活性浓度的半导体检测器。由于较低的检测下限,该设备专用于地下空间,包括洞穴,平地,矿山,要塞中的旅游路线,金字塔等。其结构允许在困难的条件下将设备运输到测量地点,以及主要由较大的环境相对湿度引起的恶劣操作条件,最高可达100%。作者介绍了这些设备的校准结果,以及它们在Sudetes(波兰SW)的洞穴和平it中的工作结果。在困难的条件下工作了将近2年之后,这些探头显示出很高的可靠性。没有观察到半导体探测器或电子设备的缺陷,从而确保了探针编程器PC装置的无故障通信。由于这一点,作者可以随意使用2年的数据库存,每小时由5个探测器记录一次。唯一不能承受极端运行条件测试的元素是组合的相对湿度和温度传感器之一。也没有观察到电源问题,并且在冬季之前每年更换一次电池。编程器也可以正常运行,从而可以将数据传输到PC,该PC对操作条件更加敏感,并且该PC已放置在远离探头暴露位置的地方。在使用更加敏感的温度,相对湿度和压力传感器之后,SRDN-3探头无疑将成为在洞穴和其他地下场所进行微气候测量(包括测量空气-大气交换)的出色工具。即使在当今,它们已经是监测地下空间中〜(222)Rn浓度的令人满意的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号