Gamma-spectrometry allows identification of a wide range of isotopes without chemical purification and is the ideal method for non-destructive techniques. The work described by S. HARB deals with the radioactivity of 238U, 226Ra, 210Pb, 228 Th, 232 Th, 228Ra, 137Cs and 40K in tea samples measured directly using gamma-spectrometer. 1 However, calculating simultaneously the activity of 232 Th, 228 Th and 228Ra by the gamma-ray peaks of 212Pb (238.63 keV), 208Tl (583.2 keV) and 228Ac (338.4, 911 and 969 keV), respectively, is basically wrong.
机译:伽马能谱仪无需化学纯化即可鉴定多种同位素,是无损技术的理想方法。 S. HARB描述的工作涉及直接使用伽马能谱仪测量的茶样品中238U,226Ra,210Pb,228 Th,232 Th,228Ra,137Cs和40K的放射性。 1但是,同时通过212Pb(238.63 keV),208Tl(583.2 keV)和228Ac(338.4、911和969 keV)的伽马射线峰同时计算232 Th,228 Th和228Ra的活性是错误的。