A virtual point source calibration method is developed to finish the calibration of voluminous sample. We used a mixed point source to get the parameters of efficiency function, obtaining the virtual position of voluminous sample. So, the detection efficiency of xenon samples and standard soil samples were calibrated by placing the point source at their virtual position. The Monte Carlo method was also used to simulate the detector efficiency of xenon samples. Deviations between the virtual source method and Monte Carlo simulation are within 2.2 % for xenon samples. Thus, we have developed two robust efficiency calibration methods based on Monte Carlo simulations and virtual point source, respectively.
机译:开发了虚拟点源校准方法以完成大量样品的校准。我们使用混合点源获取效率函数的参数,获得大量样本的虚拟位置。因此,通过将点源置于虚拟位置来校准氙样品和标准土壤样品的检测效率。蒙特卡罗方法还用于模拟氙样品的检测器效率。对于氙样品,虚拟源方法与蒙特卡洛模拟之间的偏差在2.2%以内。因此,我们分别基于蒙特卡洛模拟和虚拟点源开发了两种鲁棒的效率校准方法。