首页> 外文期刊>Journal of Radioanalytical and Nuclear Chemistry: An International Journal Dealing with All Aspects and Applications of Nuclear Chemistry >Feasibility study of FLUKA Monte Carlo simulation for a beta-emitting brachytherapy source: dosimetric parameters of Pr-142 glass seed
【24h】

Feasibility study of FLUKA Monte Carlo simulation for a beta-emitting brachytherapy source: dosimetric parameters of Pr-142 glass seed

机译:FLUKA Monte Carlo模拟用于发射β射线的近距离放射治疗源的可行性研究:Pr-142玻璃种子的剂量参数

获取原文
获取原文并翻译 | 示例
           

摘要

A series of dosimetric calculations and modeling should be done before the clinical use of any new brachytherapy source. In this work, the capability of the FLUKA Monte Carlo code to simulate praseodymium-142 glass seed as a beta-emitting brachytherapy source was evaluated. The reference dose rate, target dose rate, radial dose function and the anisotropy function were estimated. The agreement between the reported radiochromic film measurements and the FLUKA code outputs indicated that FLUKA as a multipurpose Monte Carlo simulation code can be used to predict the required dosimetric parameters reasonably well.
机译:在临床上使用任何新的近距离放射治疗源之前,应进行一系列剂量学计算和建模。在这项工作中,评估了FLUKA蒙特卡洛代码模拟142 glass玻璃作为β发射近距离放射治疗源的能力。估计了参考剂量率,目标剂量率,径向剂量函数和各向异性函数。所报告的放射致变色薄膜测量结果与FLUKA代码输出之间的一致性表明,FLUKA作为多用途的蒙特卡洛模拟代码可用于合理地预测所需的剂量参数。