...
首页> 外文期刊>Journal of plastic, reconstructive & aesthetic surgery: JPRAS >Integra? permits early durable coverage of improvised explosive device (IED) amputation stumps
【24h】

Integra? permits early durable coverage of improvised explosive device (IED) amputation stumps

机译:整合?允许尽早持久覆盖简易爆炸装置(IED)截肢树桩

获取原文
获取原文并翻译 | 示例

摘要

Introduction Improvised explosive device (IED) blasts cause serious injury. Survivors are left with multiple amputations, considerable soft tissue loss and open fractures with gross contamination. We present our early experience of Integra? in the acute management of military wounds. Method The clinical records of all patients with IED injuries who underwent early reconstruction with Integra? during the six month period between August and December 2009 in our unit were reviewed and data gathered prospectively. Results There were 7 male soldiers, aged 21-31 years (mean = 26). All sustained trunk and limb injuries, including multiple amputations. Number of procedures prior to application of Integra? was 4-10 (mean = 5). Application of Integra? took place 6-24 days post-injury (mean = 13). Size of wounds covered with Integra? was 1-11.5% TBSA (mean = 5%). Anatomical sites reconstructed included amputation stumps, and both upper and lower limbs. There was partial take of Integra in 3 wounds in 2 patients. All wounds were eventually treated with delayed split skin grafting and healed satisfactorily. Conclusion IEDs produce a large zone of injury with massive soft tissue damage, multiple discontinuous wounds which are significantly contaminated. The physiological insult is equivalent to a large cutaneous burn and there is a paucity of available donor sites. Multiple amputees also have a greater energy and power requirement1-4 and cannot spare remaining functional muscles as donors. The literature suggests that microvascular flaps have a high failure rate in military patients.5 Reconstruction began as soon as wounds were considered sufficiently clean. Integra? was applied with the aim of providing higher quality coverage than that provided by split skin grafting alone (particularly for amputation stumps) whilst minimising operative time and morbidity. Integra? allows timely closure of battlefield wounds with minimal operative time and morbidity. The procedure can begin whilst still in the acute phase and certainly before one would consider lengthy complex operations such as free flaps. Our experience suggests that Integra? can allow early closure with robust tissue, promoting early rehabilitation and return to duties.
机译:简介简易爆炸装置(IED)爆炸会造成严重伤害。幸存者需要进行多次截肢,大量软组织丢失和严重感染的开放性骨折。我们介绍我们Integra的早期经验吗?在军事伤口的急性处理中。方法所有使用Integra进行早期重建的IED损伤患者的临床记录。在2009年8月至2009年12月这6个月的时间里,我们对该单元进行了回顾,并预期地收集了数据。结果共有7名男性士兵,年龄在21-31岁之间(平均= 26)。所有躯干和四肢持续受伤,包括多次截肢。申请Integra之前需要办理多少手续?是4-10(平均值= 5)。应用Integra?发生在受伤后6至24天(平均= 13)。 Integra覆盖的伤口大小? TBSA为1-11.5%(平均值= 5%)。重建的解剖部位包括截肢残端以及上肢和下肢。在2例患者的3个伤口中部分服用了Integra。最终所有伤口均采用延迟裂开的皮肤移植术进行治疗,并令人满意地愈合。结论简易爆炸装置产生大面积的损伤,并伴有大量的软组织损伤,并造成多处不连续的伤口,受到严重污染。生理上的侮辱等同于大的皮肤烧伤,并且缺乏可用的供体部位。多个截肢者还具有更大的能量和功率需求1-4,并且不能保留剩余的功能性肌肉作为供体。文献表明,军事人员的微血管瓣修复失败率很高。5一旦认为伤口足够干净,便开始重建。整合?应用此技术的目的是提供比单独使用裂开皮肤移植(尤其是截肢残肢)更高的质量覆盖范围,同时最大程度地减少手术时间和发病率。整合?能够以最小的手术时间和发病率及时闭合战场伤口。该程序可以在仍处于急性阶段的同时开始,当然也可以在人们考虑进行漫长的复杂操作(例如自由皮瓣)之前开始。我们的经验表明,Integra?可以使早期用健壮的组织闭合,促进早期康复和恢复工作。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号