Background: To date breast assessment has been conducted mainly subjectively. However lately validated objective three-dimensional (3D) imaging was developed. The study aimed to assess breast reconstruction subjectively and objectively and conduct a comparison. Methods: In forty-four patients after immediate unilateral breast reconstruction with solely the extended latissimus dorsi flap the breast was captured by validated 3D imaging method and standardized 2D photography. Breast symmetry was subjectively evaluated by six experts who applied the Harris score giving a mark of 1-4 for a poor to excellent result. An error study was conducted by examination of the intra and inter-observer agreement and agreement on controls. By Procrustes analysis an objective asymmetry score was obtained and compared to the subjective assessment. Results: The subjective assessment showed that the inter-observer agreement was good or substantial (p-value: <0.0001). There was moderate agreement on the controls (p-value: <0.0001) and fair (p-values: 0.159, 0.134, 0.099) to substantial (p-value: 0.005) intra-observer agreement. The objective assessment revealed that the reconstructed breast showed a significantly smaller volume compared to the opposite side and that the average asymmetry score was 0.052, ranging from 0.019 to 0.136. When comparing the subjective and objective method the relationship between the two scores was highly significant. Conclusion: Subjective breast assessment lacked accuracy and reproducibility. This was the first error study of subjective breast assessment versus an objective validated 3D imaging method based on true 3D parameters. The substantial agreement between established subjective breast assessment and new validated objective method supported the value of the later and we expect its future role to expand.
机译:背景:迄今为止,乳房评估主要是主观的。然而,最近验证的物镜三维(3D)成像技术得以发展。该研究旨在主观和客观地评估乳房再造并进行比较。方法:通过有效的3D成像方法和标准化的2D摄影技术,对仅使用扩展的阔背肌皮瓣即刻单侧乳房再造术后的44例患者进行乳房捕获。六名专家对主观的乳房对称性进行了主观评估,他们使用哈里斯评分(Harris评分)将1-4评分为差至优异。通过检查观察者内部和观察者之间的协定以及关于控制的协定来进行错误研究。通过Procrustes分析,获得了客观的不对称分数,并将其与主观评估进行比较。结果:主观评估表明观察者之间的共识是良好或充分的(p值:<0.0001)。观察者内部一致同意控制(p值:<0.0001)和公平(p值:0.159,0.134,0.099)至基本(p值:0.005)。客观评估显示,与对侧相比,重建的乳房显示出明显较小的体积,平均不对称分数为0.052,范围为0.019至0.136。当比较主观和客观方法时,两个分数之间的关系非常重要。结论:主观乳房评估缺乏准确性和可重复性。这是对主观乳房评估与基于真实3D参数的经过客观验证的3D成像方法进行的第一个错误研究。既定的主观乳房评估与新的经过验证的客观方法之间的实质性协议支持了后者的价值,我们预计其未来的作用将会扩大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号