摘要

We read with great interest the recently published article by Barabas and James, utilising K-wires and cement as an external fixator for the management of hand fractures.1 The technique of using K-wires and cement as an external fixator for hand fractures was first described by Crockett in 1974.2 Since then, various modifications have been described.In our practise we routinely use a similar technique. We would like to draw readers attention that at least 1-2 cm gap between the cement block and the underlying skin should be maintained in order to prevent the risk of iatro-genic contact burn resulting from the heat generated during the chemical polymerisation of the cement (Figure 1).
机译:我们非常感兴趣地阅读了Barabas和James最近发表的文章,该文章利用K线和水泥作为外固定器来处理手部骨折。1首先使用K线和水泥作为外固定器来处理手部骨折的技术从克罗基特(Crockett)在1974.2中描述以来,已经描述了各种修改。在我们的实践中,我们通常使用类似的技术。我们想引起读者注意,在水泥块和下面的皮肤之间至少应保持1-2 cm的间隙,以防止由于水泥化学聚合过程中产生的热量而引起医源性接触灼伤的风险(图1)。