PURPOSE: To investigate objective optical quality and changes in light scatter after femtosecond laser small incision lenticule extraction (SMILE) for moderate to high myopia correction. METHODS: Prospective clinical study of 66 eyes of 66 patients (23 males, 43 females) with a mean age of 28.67 ± 6.62 years, mean spherical refraction of -6.06 ± 1.57 diopters, and mean cylindrical refraction of -0.68 ± 0.46 diopters. Every patient had a 3-month follow-up after a standard SMILE procedure. An optical quality analysis system was used to measure modulation transfer function cutoff frequency (MTFcutoff), Strehl2D ratio, and objective scatter index (OSI). RESULTS: At 3 months postoperatively, mean spherical equivalent was 0.03 ± 0.24 diopters and corrected distance visual acuities of all patients were equal to or better than preoperative values, with a mean safety index of 1.12 ± 0.17 (range: 0.80 to 1.50) and mean efficacy index of 1.18 ± 0.21 (range: 0.80 to 1.50). Mean OSI increased from 0.75 preoperatively to 1.09 at 20 days postoperatively (P .05), and gradually declined to 0.94 at 40 days and 0.82 at 3 months postoperatively (P .05). MTF cutoff and Strehl2D ratio did not change significantly compared with preoperative values (P .05). Multiple linear regression analysis revealed that preoperative OSI was significantly correlated with optical quality at 3 months. Patients with less preoperative OSI tended to acquire higher MTF cutoff (b = -8.61) and lower OSI (b = 0.65) (P .05). CONCLUSIONS: SMILE had little impact on retinal image quality after myopia correction. Postoperative OSI showed a temporary increase and then returned to normal.
机译:目的:研究飞秒激光小切口小孔镜摘除术(SMILE)用于中度至高度近视矫正后的客观光学质量和光散射变化。方法:对66例患者的66眼(男性23例,女性43例)进行前瞻性临床研究,平均年龄为28.67±6.62岁,平均球面屈光度为-6.06±1.57屈光度,平均柱面屈光度为-0.68±0.46屈光度。在标准的SMILE手术后,每位患者进行了3个月的随访。光学质量分析系统用于测量调制传递函数截止频率(MTFcutoff),Strehl2D比和目标散射指数(OSI)。结果:术后3个月,所有患者的平均球面等效度为0.03±0.24屈光度,并且矫正后的远视力等于或优于术前值,平均安全指数为1.12±0.17(范围:0.80至1.50)和平均值功效指数为1.18±0.21(范围:0.80至1.50)。术后20天平均OSI从术前0.75升高至1.09(P <.05),并在术后40天逐渐降低至0.94,在术后3个月逐渐降低至0.82(P> .05)。与术前值相比,MTF截止值和Strehl2D比率没有显着变化(P> 0.05)。多元线性回归分析显示,术前OSI与3个月时的光学质量显着相关。术前OSI较少的患者倾向于获得更高的MTF截止值(b = -8.61)和更低的OSI(b = 0.65)(P <.05)。结论:近视矫正后,SMILE对视网膜图像质量影响不大。术后OSI显示暂时升高,然后恢复正常。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号