首页> 外文期刊>Journal of refractive surgery >Aspheric intraocular lens selection based on corneal wavefront.
【24h】

Aspheric intraocular lens selection based on corneal wavefront.

机译:基于角膜波前的非球面人工晶状体选择。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To determine the feasibility of selectively targeting zero total postoperative spherical aberration by selecting the best fit aspheric intraocular lens (IOL) based on preoperative topographically derived corneal spherical aberration. METHODS: Candidates for cataract surgery were offered selection of aspheric IOLs based on corneal spherical aberration. The target postoperative total wavefront spherical aberration Z4,0 was set at zero. Corneal topographic spherical aberration Z4,0 was measured at the 6-mm optical zone, and one of three aspheric IOLs was chosen so the arithmetic sum of the corneal spherical aberration and pseudophakic spherical aberration came closest to zero. Postoperatively, total ocular wavefront was measured and statistical analysis performed to ascertain the accuracy of customized aspheric IOL selection. RESULTS: Thirty eyes of 18 patients were available for analysis. The SofPort Advanced Optics (Bausch & Lomb) lens was implanted in 1 eye, the AcrySof IQ (Alcon Laboratories Inc) in 11 eyes, and the Tecnis Z9000 or Z9002 (Advanced Medical Optics [AMO]) in 18 eyes. Total postoperative ocular spherical aberration for the entire population measured -0.013+/-0.072 microm (SofPort: +0.025 microm; AcrySof IQ: +0.010+/-0.053 microm; and Tecnis: -0.015+/-0.052 microm [P=.22]). For the entire population, mean absolute predictive error measured 0.058+/-0.056 microm (SofPort: 0.040 microm; AcrySof IQ: 0.052+/-0.040 microm; and Tecnis: 0.063+/-0.066 microm [P=.631). CONCLUSIONS: Customized selection of aspheric IOLs based on corneal wavefront is feasible and produces favorable results compared with studies of unselected patient populations implanted with aspheric IOLs.
机译:目的:通过基于术前地形学得出的角膜球面像差选择最合适的非球面人工晶状体(IOL),确定选择性靶向零总术后球面像差的可行性。方法:根据角膜球差,为白内障手术候选人提供非球面IOL的选择。术后目标总波前球面像差Z4,0设置为零。在6毫米光学区域测量角膜地形图球面像差Z4,0,并选择三个非球面IOL之一,以使角膜球面像差和伪晶状体球面像差的算术和最接近零。术后,测量总眼波前,并进行统计分析,以确定定制的非球面人工晶状体选择的准确性。结果:18例患者的三十只眼睛可供分析。 SofPort Advanced Optics(Bausch&Lomb)透镜植入1眼,AcrySof IQ(Alcon Laboratories Inc)植入11眼,Tecnis Z9000或Z9002(Advanced Medical Optics [AMO])植入18眼。整个人群的总术后眼球像差为-0.013 +/- 0.072微米(SofPort:+0.025微米; AcrySof IQ:+0.010 +/- 0.053微米; Tecnis:-0.015 +/- 0.052微米[P = .22 ])。对于整个人群,平均绝对预测误差为0.058 +/- 0.056微米(SofPort:0.040微米; AcrySof IQ:0.052 +/- 0.040微米; Tecnis:0.063 +/- 0.066微米[P = .631)。结论:与未选择的非球面人工晶状体植入患者研究相比,基于角膜波前的非球面人工晶状体定制选择是可行的,并产生了良好的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号