Factors influencing flap and INTACS decentration after femtosecond laser application in normal and keratoconic eyes.

机译:飞秒激光在正常和圆锥形圆锥形眼中影响皮瓣和INTACS偏心的因素。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To compare accuracy of LASIK flap and INTACS centration following femtosecond laser application in normal and keratoconic eyes. METHODS: This is a retrospective case series comprising 133 eyes of 128 patients referred for refractive surgery. All eyes were divided into two groups according to preoperative diagnosis: group 1 (LASIK group) comprised 74 normal eyes of 72 patients undergoing LASIK with a femtosecond laser (IntraLase), and group 2 (INTACS group) consisted of 59 eyes of 39 patients with keratoconus for whom INTACS were implanted using a femtosecond laser (IntraLase). Decentration of the LASIK flap and INTACS was analyzed using Pentacam. RESULTS: Temporal decentration was 612.56 +/- 384.24 microm (range: 30 to 2120 microm) in the LASIK group and 788.33 +/- 500.34 microm (range: 30 to 2450 microm) in the INTACS group. A statistically significant difference was noted between the groups in terms of decentration (P < .05). Regression analysis showed that the amount of decentration of the LASIK flap and INTACS correlated with the central corneal thickness in the LASIK group and preoperative sphere and cylinder in the INTACS group, respectively. CONCLUSIONS: Decentration with the IntraLase occurred in most cases, especially in keratoconic eyes. The applanation performed for centralization during IntraLase application may flatten and shift the pupil center, and thus cause decentralization of the LASIK flap and INTACS. Central corneal thickness in the LASIK group and preoperative sphere and cylinder in the INTACS group proved to be statistically significant parameters associated with decentration.
机译:目的:比较飞秒激光在正常和角膜圆锥形眼中应用LASIK皮瓣和INTACS定位的准确性。方法:这是一个回顾性病例系列,包括128例屈光手术的133眼。根据术前诊断,将所有眼睛分为两组:第一组(LASIK组)由72例接受飞秒激光(IntraLase)手术的LASIK患者组成,其中74眼为正常眼;第二组(INTACS组)由39例患者中的59眼组成使用飞秒激光(IntraLase)为其植入INTACS的圆锥形圆锥角膜。使用Pentacam分析LASIK皮瓣和INTACS的浓度。结果:LASIK组的时间分散为612.56 +/- 384.24微米(范围:30至2120微米),INTACS组的时间分散为788.33 +/- 500.34微米(范围:30至2450微米)。在偏心方面,两组之间存在统计学上的显着差异(P <.05)。回归分析表明,LASIK瓣和INTACS组的偏心量分别与LASIK组和INTACS组的术前球体和圆柱体相关。结论:在大多数情况下,尤其是在圆锥角膜眼中,使用IntraLase会引起注意力分散。在应用IntraLase期间为了集中而进行的压平可能会使瞳孔中心变平并移动,从而导致LASIK皮瓣和INTACS分散。 LASIK组和INTACS组的术前球体和圆柱体的中央角膜厚度被证明是与分散有关的统计学上重要的参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号