Early clinical outcomes of wavefront-guided myopic LASIK treatments using a new-generation Hartmann-Shack aberrometer

机译:新一代Hartmann-Shack像差仪在波前引导近视LASIK治疗中的早期临床结果

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To provide an initial retrospective evaluation of early postoperative outcomes after wavefront-guided myopic LASIK using a new-generation Hartmann-Shack wavefront sensor. METHODS: A noncomparative, retrospective study of 243 eyes of 126 patients that underwent primary wavefront-guided LASIK, using wavefront data obtained with a new Hartmann-Shack aberrometer (iDesign Advanced WaveScan aberrometer; Abbott Medical Optics, Inc., Santa Ana, CA). Visual acuity, refraction, and patient satisfaction were evaluated 1 month after surgery. RESULTS: The manifest spherical equivalent was reduced from -3.28 ± 1.79 diopters (D) (range: -9.88 to -0.38 D) before surgery to -0.03 ± 0.29 D (range: -1.00 to +1.25 D) 1 month after surgery. The manifest spherical equivalent was within 0.50 and 1.00 D of target in 93.0% and 99.6% of eyes, respectively. Manifest astigmatism preoperatively (-0.72 ± 0.67 [range: 0.0 to -5.00 D]) was reduced to -0.14 ± 0.20 (range: 0.0 to -1.00 D) at 1 month and the vector-derived correction ratio (surgically induced refractive change/intended refractive correction) was 1.02 ± 0.30. Uncorrected distance visual acuity of 20/16, 20/20, and 20/25 or better was achieved in 79.0%, 93.4%, and 96.7% of eyes, respectively. No eyes lost two or more lines of corrected distance visual acuity, whereas a gain of one or more lines was observed in 14.0%. Most patients (98.5%) reported that they were satisfied with the outcome of their procedure. CONCLUSIONS: Wavefront-guided LASIK using the new aberrometer in this retrospective evaluation was effective, safe, and predictable in the early postoperative time period for the correction of myopia with high patient satisfaction.
机译:目的:使用新一代的Hartmann-Shack波前传感器,对波前引导的近视LASIK术后早期术后结果进行初步回顾性评估。方法:使用新的Hartmann-Shack像差仪(iDesign Advanced WaveScan像差仪; Abbott Medical Optics,Inc。,加利福尼亚州圣安娜)获得的波前数据,对126例接受初次波前引导的LASIK手术的243眼的243眼进行了非比较性回顾性研究。 。术后1个月评估视力,屈光度和患者满意度。结果:明显的球体当量从术后1个月的-3.28±1.79屈光度(D)(范围:-9.88降低至-0.38 D)降低至-0.03±0.29 D(范围:-1.00至+1.25 D)。在93.0%和99.6%的眼睛中,明显的球面当量分别在目标的0.50和1.00 D之内。术前显像散(-0.72±0.67 [范围:0.0至-5.00 D])在1个月时降低至-0.14±0.20(范围:0.0至-1.00 D),并且矢量衍生的矫正率(手术引起的屈光改变/预期的屈光矫正)为1.02±0.30。分别有79.0%,93.4%和96.7%的未矫正远视力达到20 / 16、20 / 20和20/25或更高。没有眼睛损失两行或多行校正后的远距离视力,而观察到的一行或多行增加了14.0%。大多数患者(98.5%)报告对手术结果感到满意。结论:在这项回顾性评估中,使用新型像差计的波前引导LASIK在术后早期可以有效,安全且可预测地矫正高度近视的患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号