首页> 外文期刊>Journal of refractive surgery >Safety and visual outcome of visian toric ICL implantation after corneal collagen cross-linking in keratoconus
【24h】

Safety and visual outcome of visian toric ICL implantation after corneal collagen cross-linking in keratoconus

机译:圆锥形角膜胶原交联后的visic复曲面ICL植入的安全性和视觉效果

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To evaluate the safety and clinical outcome of phakic Visian toric implantable collamer lens (ICL) (STAAR Surgical, Monrovia, CA) insertion after corneal collagen cross-linking (CXL) in progressive keratoconus. METHODS: A retrospective study examined the results of the two-step CXL and Visian toric ICL implantation in 16 eyes of 10 patients with keratoconus. The two procedures were done at an interval of 6 months. Data were collected preoperatively, at the 6-month follow-up visit after CXL, and at the 6-month follow-up visit after ICL implantation. RESULTS: CXL induced a statistically significant decrease in steep keratometry (50.02 ?? 4.07 at baseline to 48.74 ?? 4.05 at 6 months after CXL, P = .001) without any significant change in visual acuity or refraction. At 6-month follow-up after ICL implantation, mean K (max) was 50.49 ?? 4.07 versus 52.29 ?? 4.79 D at baseline (P = .001). Mean uncorrected distance visual acuity improved from 1.67 ?? 0.49 to 0.17 ?? 0.06 logMAR (P = .001) and mean corrected distance visual acuity improved from 0.15 ?? 0.06 to 0.12 ?? 0.04 logMAR (P = .023). Mean spherical equivalent decreased from -7.24 ?? 3.53 to -0.89 ?? 0.76 D (P = .001) and mean cylinder decreased from 2.64 ?? 1.28 to 1.16 ?? 0.64 D (P = .001). The safety and efficacy indices were 1.08 ?? 0.13 and 0.97 ?? 0.08, respectively. No intraoperative or postoperative complications occurred. CONCLUSIONS: Implantation of the Visian toric ICL following CXL is an effective option for improving visual acuity in patients with keratoconus.
机译:目的:评估渐进性圆锥角膜中角膜胶原交联(CXL)后插入有晶状Visian复曲面复曲面植入式晶状体透镜(ICL)(STAAR Surgical,Monrovia,CA)的安全性和临床结果。方法:一项回顾性研究检查了10例圆锥角膜病患者16眼的两步CXL和Visian复曲面ICL植入的结果。两次操作间隔为6个月。术前,CXL术后6个月随访和ICL植入6个月随访时收集数据。结果:CXL引起的角膜曲率测定具有统计学上的显着降低(基线时为50.02≤4.07,CXL术后6个月时为48.74≤4.05,P = .001),而视力或屈光度没有任何显着变化。 ICL植入后的6个月随访中,平均K(最大值)为50.49 ??。 4.07和52.29 ??基线为4.79 D(P = 0.001)。平均未矫正远视力从1.67改善0.49至0.17 ?? 0.06 logMAR(P = .001),平均矫正距离视力从0.15 ??提高到0.06至0.12 ?? 0.04 logMAR(P = .023)。平均球当量从-7.24降低3.53至-0.89 ?? 0.76 D(P = .001),平均气缸从2.64? 1.28至1.16 ?? 0.64 D(P = .001)。安全性和有效性指数为1.08 ?? 0.13和0.97 ??分别为0.08。没有发生术中或术后并发症。结论:CXL术后植入Visian复曲面ICL是改善圆锥角膜患者视敏度的有效选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号