PURPOSE: To determine the higher order aberrations following implantation of four foldable intraocular lens (IOL) designs. METHODS: One hundred twenty-two eyes were randomly assigned to undergo implantation with one of four foldable IOL designs--Collamer (STAAR Surgical, Monrovia, Calif), plate haptic silicone (STAAR Surgical), AcrySof (Alcon, Ft Worth, Tex), or the Sensar (Advanced Medical Optics, Santa Ana, Calif). All enrolled eyes underwent wavefront assessment using the Tracey Visual Function Analyzer (Tracey Technologies, Houston, Tex). RESULTS: Preoperatively, no significant differences were noted in higher order aberrations between the four lens groups. No significant differences were noted among the plate haptic silicone, Sensar, or AcrySof lenses at 1 week or 1 month postoperatively, or among the Collamer, plate haptic silicone, or Sensar lenses, with regard to total higher order aberrations, although differences were observed in individual aberration terms. At 1 week and 1 month postoperatively, the Collamer IOL had significantly less higher order aberrations than the AcrySof lens (P < .01). Significantly less third and fourth order aberrations, coma, trefoil, spherical aberration, and tetrafoil were observed postoperatively with the Collamer than the AcrySof IOL. There were no parameters where the AcrySof had significantly less optical aberrations than the Collamer. CONCLUSIONS: The Collamer IOL design is associated with fewer higher order aberrations than the AcrySof lens.
机译:目的:确定植入四个可折叠人工晶状体(IOL)设计后的高阶像差。方法:将一百二十二只眼随机分配给四种可折叠IOL设计之一进行植入-Collamer(STAAR Surgical,Monrovia,Calif),平板触觉硅树脂(STAAR Surgical),AcrySof(Alcon,Ft Worth,Tex)或Sensar(先进医疗光学,加利福尼亚州圣安娜)。使用Tracey视觉功能分析仪(Tracey Technologies,休斯敦,得克萨斯州)对所有登记的眼睛进行波前评估。结果:术前,四个镜片组之间的高阶像差没有显着差异。术后1周或1个月,平板触觉硅树脂,Sensar或AcrySof镜片之间以及Collamer,平板触觉硅树脂或Sensar镜片之间的总高阶像差没有显着差异,尽管在个人像差条款。术后1周和1个月,Collamer IOL的高阶像差明显低于AcrySof晶状体(P <.01)。术后用Collamer观察到的三阶和四阶像差,彗形,三叶形,球面像差和四翼形像差于AcrySof IOL。没有参数,AcrySof的光学像差比Collamer小得多。结论:与AcrySof镜头相比,Collamer IOL设计与更少的高阶像差相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号