首页> 外文期刊>Journal of refractive surgery >Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses.
【24h】

Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses.

机译:植入五种不同人工晶状体的眼睛的波前像差和光学质量的比较。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: We compared corneal and total higher order wavefront aberrations in 25 pseudophakic eyes implanted with five different types of intraocular lenses to obtain an objective evaluation of the optical quality of these pseudophakic eyes. Five IOLs per type were studied. METHODS: Implanted lenses were the Pharmacia Tecnis Z9000 with negative spherical aberration, Pharmacia 911 Edge, Alcon Acrysof SA60AT and MA60BM, and Allergan Sensar AR40e. Eyes were examined using the Topcon KR-9000PW topographer/aberrometer, which obtains simultaneous coaxial measurements of corneal and ocular aberrations, and displays the calculated Point Spread Function (PSF) and Modulation Transfer Function (MTF). RESULTS: Corneal spherical aberration was positive in all tested eyes. For a 4-mm optical zone, ocular spherical aberration was 0.0054+/-0.0172 microm root-mean-square (RMS) in eyes implanted with the Tecnis lens, and was 0.0562 to 0.0974 microm RMS in eyes implanted with the four other conventional IOLs. A myopic refractive shift with mydriasis of -0.08 D occurred with the Tecnis IOL; it was -0.57 to -0.90 D with the conventional IOLs. Coma did not show a substantial reduction with any of the IOLs. Total wavefront aberrations showed nonsignificant reduction with the Tecnis lens. The PSF and the MTF also showed nonsignificant improvements over conventional IOLs. CONCLUSIONS: The optical quality of pseudophakic eyes can be measured in vivo by aberrometers. Different IOLs resulted in measurably different outcomes. In this preliminary study, compensation of the spherical aberration observed with the Tecnis lens confirmed the theoretical predictions associated with this lens and resulted in no myopic shift in refraction with mydriasis.
机译:目的:我们比较了植入了五种不同类型的人工晶状体的25只假晶状体眼的角膜和总高阶波前像差,从而客观评估了这些假晶状体眼的光学质量。每个类型研究了五个IOL。方法:植入的镜片为具有负球差的Pharmacia Tecnis Z9000,Pharmacia 911 Edge,Alcon Acrysof SA60AT和MA60BM以及Allergan Sensar AR40e。使用Topcon KR-9000PW地形图仪/像差仪检查眼睛,该仪同时获得角膜和眼像差的同轴测量,并显示计算的点扩展函数(PSF)和调制传递函数(MTF)。结果:所有被测眼角膜球差均为阳性。对于4毫米的光学区域,在植入Tecnis晶状体的眼睛中,眼球差为0.0054 +/- 0.0172微米均方根(RMS),在植入其他四种常规IOL的眼睛中为0.0562至0.0974微米RMS。 。 Tecnis IOL发生散瞳为-0.08 D的近视屈光度;传统IOL为-0.57至-0.90D。任何IOL均未显示昏迷明显减少。使用Tecnis透镜,总波前像差没有明显降低。 PSF和MTF也比常规IOL表现出无明显改进。结论:可通过像差仪在体内测量假晶状体眼的光学质量。不同的IOL导致明显不同的结果。在这项初步研究中,用Tecnis镜片观察到的球差补偿可以证实与该镜片相关的理论预测,并且不会导致散瞳引起的近视移位。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号