...
首页> 外文期刊>Journal of refractive surgery >Corneal first surface wavefront aberrations before and after pterygium surgery.
【24h】

Corneal first surface wavefront aberrations before and after pterygium surgery.

机译:翼状surgery肉手术前后角膜的第一表面波前像差。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To determine the higher order aberrations at the corneal first surface before and after surgery for pterygium. METHODS: Data were drawn from a longitudinal study of patients undergoing pterygium excision at Royal Victoria Infirmary, Newcastle upon Tyne, England between September 1998 and May 2004. Corneal topography was taken with the TMS-2 Topographic Modeling System (Computed Anatomy Corp) prior to and 6 months after surgery, exported to VOLPro software v7.08 (Sarver & Associates), and wavefront aberrations were derived for a 5.0-mm pupil using a 10th order Zernike polynomial expansion. Pre- to postoperative changes were assessed for significance using analyses of variance, and the relative risk of significant postoperative aberrations by pterygium size was determined. RESULTS: Satisfactory corneal topography was available on 67 eyes (mean age 53.8 +/- 16.7 years [range: 25-86 years]). The root-mean-square (RMS) fit error in preoperative eyes was 0.15 +/- 0.10 microm. Preoperatively, the total higher order RMS wavefront aberration was 0.94 +/- 0.83 microm. All Zernike modes were elevated, with trefoil being the major contributor 0.52 +/- 0.50 microm. Pterygium excision significantly reduced wavefront aberrations across all modes and orders (F(1, 129) = 6.7 to 22.6, P < .01): total higher order RMSpostop 0.45 +/- 0.35 microm. Cases with visually significant postoperative aberrations occurred and were more likely with larger pterygia: relative risk compared to pterygia 1.0 to 1.9 mm was 1.3 for 2.0 to 2.9 mm, 8.5 for 3.0 to 3.9 mm, 13.3 for 4.0 to 4.9 mm, and 10.2 for 5.0 to 5.9 mm. CONCLUSIONS: Zernike polynomial fitting well describes wavefront aberrations in eyes with pterygia. Pterygia are associated with wavefront aberrations, especially trefoil, but these were largely eliminated by surgery. Earlier excision of pterygia reduces the likelihood of significant residual aberrations.
机译:目的:确定翼状ery肉手术前后角膜第一表面的高阶像差。方法:数据来自于1998年9月至2004年5月在英国泰恩河畔纽卡斯尔的皇家维多利亚医务室进行翼状exc肉切除术的患者的纵向研究。在使用TMS-2地形建模系统(计算机解剖公司)之前对角膜地形图进行了拍摄。手术后6个月,导出到VOLPro软件v7.08(Sarver&Associates),并使用10阶Zernike多项式展开式获得了一个5.0毫米瞳孔的波前像差。使用方差分析评估术前至术后变化的意义,并确定翼状size肉大小引起的术后畸变的相对风险。结果:67眼可获得满意的角膜地形图(平均年龄53.8 +/- 16.7岁[范围:25-86岁])。术前眼睛的均方根(RMS)拟合误差为0.15 +/- 0.10微米。术前,总的高阶RMS波前像差为0.94 +/- 0.83微米。所有的泽尼克模式都升高了,三叶起主要作用是0.52 +/- 0.50微米。翼状exc肉切除显着降低了所有模式和阶数下的波前像差(F(1,129)= 6.7至22.6,P <.01):总的高阶RMSpostop为0.45 +/- 0.35微米。发生视觉上明显的术后畸变的病例,更可能是更大的翼状:肉:与1.0至1.9 mm的翼状compared肉相比,相对风险为2.0至2.9 mm的1.3、3.0至3.9 mm的8.5、4.0至4.9 mm的13.3和5.0的10.2至5.9毫米结论:Zernike多项式拟合很好地描述了翼状eyes肉眼中的波前像差。翼状y肉与波前畸变有关,尤其是三叶形畸变,但是这些在很大程度上被手术消除了。早期切除翼状reduces肉可减少出现严重残余像差的可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号