首页> 外文期刊>Clinical imaging >Liver volume measurement by spiral CT: an in vitro study.
【24h】

Liver volume measurement by spiral CT: an in vitro study.

机译:螺旋CT测量肝脏体积:一项体外研究。

获取原文
获取原文并翻译 | 示例
           

摘要

Liver volume measurement has many clinical and research uses. The purpose of the present study is to evaluate experimentally the accuracy and reproducibility of spiral computed tomography (CT) in measuring liver volume. To determine the accuracy of spiral CT system, nine fresh (non-formalin-fixed) sheep livers were scanned in vitro. The collimation was 7 mm. The CT sections were stored on floppy disks and the images were transferred to the workstation that contained a software for volume measurement. The mean volume is 912+/-497 ml and the actual reference volume is 921+/-527 ml. The correlation between the CT system and actual reference measurement of sheep liver volumes was very strong. The correlation coefficient r was.998 (P<.001) on 7-mm sections. The mean difference between liver volume measurements was 4.95+/-3.23%. As a result, CT scan could be used as a reference noninvasive method for liver volume measurement in clinics.
机译:肝体积测量具有许多临床和研究用途。本研究的目的是通过实验评估螺旋CT(CT)在测量肝脏体积中的准确性和可重复性。为了确定螺旋CT系统的准确性,在体外扫描了九个新鲜的(非福尔马林固定的)绵羊肝脏。准直为7mm。 CT部分存储在软盘中,图像被传输到包含用于体积测量的软件的工作站。平均体积为912 +/- 497毫升,实际参考体积为921 +/- 527毫升。 CT系统与羊肝体积的实际参考值之间的相关性非常强。在7毫米截面上的相关系数r为0.998(P <.001)。肝脏体积测量之间的平均差异为4.95 +/- 3.23%。因此,CT扫描可用作临床中肝脏体积测量的参考非侵入性方法。