In the food and dairy industries, aerobic plate counts are determined by a time-consuming and laborious hand-counting method. The PetriScan ~Rautomated colony counter was developed to improve efficiency in the microbiology laboratory. In this study, colony counts of food, dairy, and milk products plated on 3M~(TM)Petrifll~(TM) Aerobic Count Plates were compared using both automated and manual count plate methods. For sample variation, 16 different food, dairy, and milk products were used. Samples were prepared and serially diluted using Butterfield's diluent according to approved AOAC methods and APHA's Standard Methods. Plates were inoculated, incubated, and counted according to AOAC methods. For data collection, plates with counts between 5 and 300 colonies were included. A total of 55 low (5-30), 29 medium (31-100), and 23 high (101-300) count plates were used. Duplicate results were recorded for both methods; hand counts were tallied by two scientists. The duplicates of the mean log values formanual counts varied by 0.0005 and 0.0007, and the duplicates for the automated counts varied by 0.0011. The mean log value difference between the automated and manual counts for pooled data was 0.035. The correlation coefficient for the regression linecomparing the automated and manual count methods for pooled data was 0.98. The regression equation was y=0.9257 + 0.0781. These results demonstrate that the PetriScan~R automated colony counter is a comparable and practical alternative to the standard method of manually counting plates.
机译:在食品和奶制品行业,需氧板数是通过费时费力的手动计数方法确定的。开发了PetriScan〜Rautomated菌落计数器,以提高微生物实验室的效率。在这项研究中,使用自动和手动计数板方法比较了镀在3M〜Petrifll〜(TM)好氧计数板上的食品,乳制品和奶制品的菌落计数。对于样品变化,使用了16种不同的食品,乳制品和奶制品。根据批准的AOAC方法和APHA的标准方法,准备样品并使用Butterfield稀释剂进行系列稀释。接种板,孵育,并根据AOAC方法计数。为了收集数据,包括计数在5到300个菌落之间的板。总共使用了55个低(5-30),29个中(31-100)和23个高(101-300)计数板。两种方法均记录了重复的结果。两位科学家计算了笔数。手动计数的平均对数值的重复项的变化范围为0.0005和0.0007,自动计数的平均对数值的重复项的范围为0.0011。合并数据的自动计数和手动计数之间的平均日志值差异为0.035。回归线与汇总数据的自动计数方法和手动计数方法相比的相关系数为0.98。回归方程为y = 0.9257 + 0.0781。这些结果表明,PetriScan〜R自动菌落计数器是手动计数板的标准方法的可比且实用的替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号