...
首页> 外文期刊>Clinical hemorheology and microcirculation >Osteocutaneous free flaps: a critical analysis of quantitative evaluation of bone microcirculation with contrast-enhanced high resolution ultrasound (hrCEUS) and TIC analysis.
【24h】

Osteocutaneous free flaps: a critical analysis of quantitative evaluation of bone microcirculation with contrast-enhanced high resolution ultrasound (hrCEUS) and TIC analysis.

机译:游离皮瓣:利用对比增强型高分辨率超声(hrCEUS)和TIC分析定量评估骨微循环的关键分析。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: Osteocutaneous free flaps (OFF) are widely used to reconstruct large bone defects in trauma and cancer surgery. Currently no monitoring method is available to detect blood circulation around and inside the bone after transplantation. Therefore we used for the first time contrast-enhanced high-resolution ultrasound (hrCEUS) to gain evidence for the microcirculation of the transplanted bone. MATERIALS AND METHODS: 15 patients transplanted with OFF because of large bone defects at different sites were examined postoperatively with hrCEUS with a high resolution linear probe (6-9 MHz, LOGIQ E9/GE) and a bolus injection of 2.4 ml of contrast agent (SonoVue(R), Bracco, Italy). Operation and examination were performed by either an experienced plastic surgeon or an experienced ultrasound examiner. Microcirculation of the periost and bone was analyzed in different regions of interest (ROIs) and quantitative microcirculation analysis was performed using time intension curve analysis (TIC). We further analyzed clinical outcome of the patients in respect to revision-surgery, necrosis of the OFF and flap survival as well as viability on standard x-rays 2 months after surgery. RESULTS: The most representative parameter by TIC analysis of hrCEUS were the area under the curve (AUC) and the time to peak (Ttop). The AUC of the periost and central part of the bone showed a high correlation (Pearson's r = 0.831). Mean AUC for the periost was 163.92 dB +/- 49.44 and for the central part of the bone 70.42 dB +/- 25.33. The Ttop of the periosteal ROI was 33.04 sec. +/- 6.71 and the bone ROI 41.01 sec. +/- 9.24. There was a high correlation of the Ttop of the periost and bone (Pearson's r = 0.937). One revision had to be performed due to haematoma and microcirculation defect of the distal part of the transplanted bone graft which was detected early by hrCEUS and the distal part of the avital bone could be removed timely. CONCLUSION: For the first time we could show that hrCEUS is a reliable method to evaluate the viability of OFF. The AUC and Ttop seem to be a valuable parameter to detect the microcirculation around and inside the bone transplant.
机译:目的:游离皮肤皮瓣(OFF)被广泛用于重建创伤和癌症手术中的大骨缺损。当前,没有监测方法可用于检测移植后骨头周围和内部的血液循环。因此,我们首次使用造影剂增强型高分辨率超声(hrCEUS)来获得移植骨微循环的证据。材料与方法:对15例因不同部位大骨缺损而行OFF手术的患者在hrCEUS术后进行了高分辨率线性探针(6-9 MHz,LOGIQ E9 / GE)和大剂量注射2.4 ml造影剂的检查( (意大利,布拉科,SonoVue(R))。由经验丰富的整形外科医生或经验丰富的超声检查员进行手术和检查。在不同的目标区域(ROIs)中分析骨膜和骨骼的微循环,并使用时间强度曲线分析(TIC)进行定量的微循环分析。我们进一步分析了患者在翻修手术,OFF坏死和皮瓣存活以及术后2个月的标准X射线检查方面的临床结果。结果:hrCEUS的TIC分析中最具代表性的参数是曲线下的面积(AUC)和达到峰值的时间(Ttop)。骨膜和骨中央部分的AUC显示出很高的相关性(Pearson r = 0.831)。骨膜的平均AUC为163.92 dB +/- 49.44,骨的中部为70.42 dB +/- 25.33。骨膜ROI的Ttop为33.04秒。 +/- 6.71和骨骼ROI 41.01秒。 +/- 9.24。骨膜的Ttop与骨骼的Ttop高度相关(Pearson r = 0.937)。由于血肿和移植骨移植物远端的微循环缺陷(必须通过hrCEUS尽早发现),必须进行一次修订,并且可以及时切除鸟骨的远端。结论:我们首次证明hrCEUS是评估OFF生存力的可靠方法。 AUC和Ttop似乎是检测骨移植周围和内部微循环的重要参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号