A simple and modern method for simultaneous analysis of nitrite and nitrate in whole blood has been devised by ion chromatography with an autosuppressor and a conductivity detector. To our knowledge, this is the first report for such analysis dealing with whole blood as a specimen. A 1 mL volume of whole blood was mixed with 2 mL of Milli Q water, vortex-mixed for hemolysis, and ultrafiltered to obtain a clear extract solution. It was passed through double connected mini-cartridges of silver resin and a silver absorbing material to remove a high concentration of chloride ion usually present in whole blood. An aliquot of the filtrate was analyzed on a Dionex DX-500 instrument with a microbore IonPac((R)) AS9-HC column (2 x 250 mm). The present method gave very low backgrounds for blank whole blood at locations where nitrite should appear, and around the endogenous peak of nitrate. The spiked nitrite markedly decreased in whole blood, probably by the action of hemoglobin in vitro; it was only 10-20% 2 h after the addition. Therefore, quantitative validation had to be made only for nitrate. The recoveries of nitrate from whole blood were more than 90%; the linearity was confirmed in the range of 5-100 mu g mL(-1) for whole blood. Detection limit of nitrate in whole blood was about 0.5 mu g mL(-1). Coefficients of intra- and inter-day variations were 3.66-7.14%. Using the present method, nitrite and nitrate concentrations were measured for human blood specimens after sniffing isobutyl nitrite gas in two male subjects. The endogenous nitrate concentrations without such sniffing were 1.27 to 7.60 mu g mL(-1) for seven subjects.
机译:通过带有自动抑制器和电导检测器的离子色谱法,已经设计出一种同时分析全血中亚硝酸盐和硝酸盐的简单现代方法。据我们所知,这是将全血作为样本进行此类分析的第一份报告。将1 mL体积的全血与2 mL Milli Q水混合,涡旋混合进行溶血,然后超滤以获得澄清的提取液。将其通过银树脂和银吸收材料的双连接微型墨盒,以去除全血中通常存在的高浓度氯离子。在带有微孔AS9-HC柱(2×250mm)的Dionex DX-500仪器上分析滤液的等分试样。本方法在应出现亚硝酸盐的位置以及硝酸盐的内源性峰周围给出了空白全血的极低背景。全血中加标的亚硝酸盐明显减少,可能是由于体外血红蛋白的作用。加入后2小时仅10-20%。因此,仅对硝酸盐进行定量验证。全血中硝酸盐的回收率超过90%;对于全血,线性在5-100μg mL(-1)范围内。全血中硝酸盐的检出限约为0.5μg mL(-1)。日内和日间变动系数为3.66-7.14%。使用本发明的方法,在两名男性受试者中嗅闻亚硝酸异丁酯气体后,测量了人体血液样本中的亚硝酸盐和硝酸盐浓度。对于七名受试者,没有这种嗅探的内源性硝酸盐浓度为1.27至7.60μg mL(-1)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号