We report studies of the coagulation of samples of whole human blood by oscillatory shear techniques, including Fourier Transform Mechanical Spectroscopy (FTMS). These techniques are used herein to identify the Gel Point of coagulating blood in terms of the Chambon-Winter Gel Point criterion which provides a rheometrical basis for detecting the establishment of an incipient clot. A comparison of the results of FTMS with those obtained from measurements involving a Thromboelastograph (TEG) and a Free Oscillation Rheometer (FOR) indicate that the latter techniques are not capable of detecting the incipient clot, whose establishment occurs several minutes prior to TEG or FOR-based assessments of clot formation time. The results of the present study suggest that FTMS is a useful tool in blood clotting research, being capable of providing a global coagulation profile in addition to detecting the instant of incipient clot formation.
机译:我们报告了通过振荡剪切技术,包括傅里叶变换机械光谱学(FTMS),对全人类血液样本的凝结研究。这些技术在本文中用于根据Chambon-Winter凝胶点标准来识别凝结的血液的凝胶点,该标准为检测初期血凝块的建立提供了流变学基础。将FTMS的结果与通过血栓弹性描记仪(TEG)和自由振荡流变仪(FOR)进行测量得到的结果进行比较表明,后一种技术无法检测初期血凝块,后者的建立早于TEG或FOR基于血块形成时间的评估。本研究的结果表明,FTMS是凝血研究中的有用工具,除了可以检测初期血块形成的瞬间外,还可以提供全面的凝血特性。