首页> 外文期刊>Journal of prosthodontics: official journal of the American College of Prosthodontists >Influence of abutment type and esthetic veneering on preload maintenance of abutment screw of implant-supported crowns
【24h】

Influence of abutment type and esthetic veneering on preload maintenance of abutment screw of implant-supported crowns

机译:基台类型和美学饰面对种植体支撑牙冠基台螺丝预紧维护的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: The effect of veneering materials on screw joint stability remains inconclusive. Thus, this study evaluated the preload maintenance of abutment screws of single crowns fabricated with different abutments and veneering materials. Materials and Methods: Sixty crowns were divided into five groups (n = 12): UCLA abutment in gold alloy with ceramic (group GC) and resin (group GR) veneering, UCLA abutment in titanium with ceramic (group TiC) and resin (group TiR) veneering, and zirconia abutment with ceramic veneering (group ZiC). Abutment screws made of gold were used with a 35 Ncm insertion torque. Detorque measurements were obtained initially and after mechanical cycling. Data were analyzed by ANOVA and Fisher's exact test at a significance level of 5%. Results: For the initial detorque means (in Ncm), group TiC (21.4 ± 1.78) exhibited statistically lower torque maintenance than groups GC (23.9 ± 0.91), GR (24.1 ± 1.34), and TiR (23.2 ± 1.33) (p < 0.05, Fisher's exact test). Group ZiC (21.9 ± 2.68) exhibited significantly lower torque maintenance than groups GC, GR, and TiR (p < 0.05, Fisher's exact test). After mechanical cycling, there was a statistically significant difference between groups TiC (22.1 ± 1.86) and GR (23.8 ± 1.56); between groups ZiC (21.7 ± 2.02) and GR; and also between groups ZiC and TiR (23.6 ± 1.30) (p < 0.05, Fisher's exact test). Conclusions: Detorque reduction occurred regardless of abutment type and veneering material. More irregular surfaces in the hexagon area of the castable abutments were observed. The superiority of any veneering material concerning preload maintenance was not established.
机译:目的:饰面材料对螺钉接头稳定性的影响尚无定论。因此,本研究评估了用不同基台和饰面材料制成的单个牙冠的基台螺丝的预紧维护。材料和方法:60个冠分为五个组(n = 12):陶瓷合金(GC组)和树脂(GR组)金合金中的UCLA基台,陶瓷(TiC组)和树脂(钛组)中钛金属的UCLA基台。 TiR)饰面,以及带有陶瓷饰面的氧化锆基台(ZiC组)。使用金制的基台螺丝,插入扭矩为35 Ncm。最初和在机械循环之后获得扭矩测量值。通过ANOVA和Fisher精确检验对数据进行分析,显着性水平为5%。结果:对于初始扭矩平均值(单位为Ncm),TiC组(21.4±1.78)的扭矩维持率在统计学上低于GC组(23.9±0.91),GR(24.1±1.34)和TiR(23.2±1.33)(p < 0.05,费舍尔精确检验)。 ZiC组(21.9±2.68)的扭矩维持率明显低于GC,GR和TiR组(p <0.05,Fisher精确检验)。机械循环后,TiC组(22.1±1.86)和GR组(23.8±1.56)之间存在统计学差异。 ZiC(21.7±2.02)和GR之间;以及在ZiC和TiR组之间(23.6±1.30)(p <0.05,Fisher精确检验)。结论:无论基台类型和饰面材料如何,都可以降低扭矩。在可浇铸基台的六边形区域中观察到更多不规则表面。没有任何涉及预载维护的饰面材料的优越性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号