首页> 外文期刊>Clinical imaging >Cardiovascular computed tomography angiography in newborns and infants with suspected congenital heart disease: Retrospective evaluation of low-dose scan protocols
【24h】

Cardiovascular computed tomography angiography in newborns and infants with suspected congenital heart disease: Retrospective evaluation of low-dose scan protocols

机译:怀疑患有先天性心脏病的新生儿和婴儿的心血管CT血管造影:低剂量扫描方案的回顾性评估

获取原文
获取原文并翻译 | 示例

摘要

Twelve infants (body weight, 3.59±1.36 kg) with congenital heart disease underwent a clinically indicated cardiovascular computed tomography angiography (CTA) study. Retrospectively, we investigated the feasibility and diagnostic capability of different non-electrocardiogram-triggered CTA protocols and assessed radiation doses. Scans were performed on a 256-multislice CT (MSCT) scanner with the vendor-preset helical protocol at 120 kV for babies, with axial single-shoot scans at 120 kV and 80 kV. The 80-kV protocol led to significantly reduced mean effective doses of 0.29±0.08 mSv (P=.017) and renders diagnostic image quality. All major cardiovascular defects were detected on MSCT, and all images were of diagnostic quality.
机译:12名先天性心脏病的婴儿(体重3.59±1.36千克)接受了临床指示的心血管计算机断层扫描血管造影(CTA)研究。回顾性地,我们调查了不同的非心电图触发的CTA方案的可行性和诊断能力,并评估了辐射剂量。扫描是在256多层CT(MSCT)扫描仪上进行的,使用的是婴儿预先设定的螺旋协议,婴儿的扫描电压为120 kV,轴向单次扫描的扫描电压为120 kV和80 kV。 80 kV方案导致平均有效剂量显着降低了0.29±0.08 mSv(P = .017),并提供了诊断图像质量。在MSCT上检测到所有主要的心血管缺陷,所有图像均具有诊断质量。