首页> 外文期刊>Journal of prosthodontics: official journal of the American College of Prosthodontists >High performance liquid chromatographic determination of residual monomer released from heat-cured acrylic resin: An in vivo study
【24h】

High performance liquid chromatographic determination of residual monomer released from heat-cured acrylic resin: An in vivo study

机译:高效液相色谱法测定从热固化丙烯酸树脂中释放的残留单体:体内研究

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: Heat-polymerized acrylic resins are used in dentistry for complete denture fabrication. Despite the polymerization method, conversion of monomer into polymer is often incomplete with free or unreacted residual monomer remaining in the polymerized resin. The aim of this study was to determine the amount of residual monomeric methyl methacrylate (MMA) leaching in the saliva of patients wearing complete dentures in their postinsertion period. Materials and Methods: Thirty edentulous participants as first-time complete denture wearers (age 60 to 65 years) were selected. All the prostheses were fabricated using a similar standard technique with a heat-cured acrylic resin denture base material. Saliva samples were collected at time intervals of 1 hour, 1 day, and 3 days postdenture insertion. Participants were asked to discharge saliva every 30 seconds into a pre-weighed screw-capped container for a 5-minute period. MMA levels were measured using high performance liquid chromatography. Data were analyzed by ANOVA and Tukey-HSD. Results: The maximum concentration of monomer released into saliva peaked 1 day after insertion of the complete dentures. The mean (SD) MMA content was 0.04 ± 0.01 (μg/ml) 1 hour after insertion, and 0.3 ± 0.09 (μg/ml), and 0.05 ± 0.01 (μg/ml) on the first and third days postinsertion, respectively. Conclusions: Although the released monomeric MMA was not at toxic levels, it could potentially sensitize complete denture patients or elicit an allergic reaction. The risk of the residual material as a primary irritant for a sensitizing reaction could be minimized by immersion of the denture in water for 24 hours before insertion.
机译:目的:牙科中使用热聚合丙烯酸树脂来完成义齿的制作。尽管采用了聚合方法,单体转化为聚合物通常仍不完全,而游离或未反应的残留单体仍残留在聚合树脂中。这项研究的目的是确定在插入后使用全口义齿的患者唾液中残留的甲基丙烯酸甲酯单体(MMA)的浸出量。材料和方法:选择30名无牙的参与者作为首次完全义齿佩戴者(年龄60至65岁)。所有假体均使用与热固化丙烯酸树脂假牙基体材料相似的标准技术制造。假牙插入后1小时,1天和3天的时间间隔收集唾液样品。要求参与者每30秒将唾液排入预先称重的旋盖容器中,持续5分钟。 MMA水平使用高效液相色谱法测量。通过ANOVA和Tukey-HSD分析数据。结果:插入完整义齿后1天,释放到唾液中的单体最大浓度达到峰值。插入后1小时的平均(SD)MMA含量为0.04±0.01(μg/ ml),插入后第一天和第三天分别为0.3±0.09(μg/ ml)和0.05±0.01(μg/ ml)。结论:尽管释放的单体MMA的毒性水平不高,但它可能使完整的义齿患者敏感或引起过敏反应。通过在插入前将义齿在水中浸泡24小时,可以将残留材料作为敏化反应的主要刺激物的风险降至最低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号