Mechanical Properties of Polyamide Versus Different PMMA Denture Base Materials

机译:聚酰胺与不同的PMMA义齿基料的力学性能

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Purpose: Polymethyl methacrylate (PMMA) resins are the most commonly used denture materials; however, they do not have a high flexural strength (FS). This study aimed to compare the mechanical properties of a polyamide-based, injection-molded denture material (Deflex) with another injection-molded PMMA base material (SR-Ivocap) and a conventional compression-molded PMMA (Meliodent). Materials and Methods: Flexural properties (deflection, bending strength, and bending modulus) of denture base materials were evaluated (n = 10). Specimens meeting International Standards Organization (ISO) specification number 20795-1 requirements were prepared (65 × 10 × 3 mm 3). A three-point bending test was carried out on an Instron testing machine at a 5 mm/min crosshead speed. The Knoop hardness test was used to compare microhardness values. Data were analyzed using ANOVA, followed by REGWQ. Results: The group results, standard deviations, and statistical differences (p 0.01) for Deflex, SR-Ivocap, and Meliodent were (A) flexural strength (MPa: 78.3 ± 1.0, a 69.8 ± 1.4, b 81.1 ± 1 a), (B) flexural modulus (GPa: 0.70 ± 0.13, a 0.85 ± 0.27, a 1.70 ± 0.23 b), (C) Knoop Hardness (kg/cm 2: 7.5 ± 1.0, a 13.5 ± 1.4, b 16.9 ± 1.0 c). Different superscript letters indicate significant difference. All Meliodent specimens fractured during flexural testing, but no Deflex specimens did. Conclusions: While polyamide denture material produced good fracture resistance, its modulus is not yet sufficiently high to be equal to standard PMMA materials. Clinical Implications. Polyamide has some attractive advantages, but will require modification to produce consistently better properties than current PMMA materials.
机译:目的:聚甲基丙烯酸甲酯(PMMA)树脂是最常用的义齿材料。但是,它们没有很高的抗弯强度(FS)。这项研究旨在比较聚酰胺基注射成型义齿材料(Deflex)与另一种注射成型PMMA基础材料(SR-Ivocap)和常规压缩成型PMMA(Meliodent)的机械性能。材料和方法:评估义齿基材的弯曲性能(挠度,弯曲强度和弯曲模量)(n = 10)。准备了符合国际标准组织(ISO)规范编号20795-1要求的标本(65×10×3 mm 3)。在Instron测试机上以5 mm / min的十字头速度进行三点弯曲测试。努氏硬度测试用于比较显微硬度值。使用ANOVA,然后使用REGWQ对数据进行分析。结果:Deflex,SR-Ivocap和Meliodent的组结果,标准偏差和统计学差异(p <0.01)为(A)抗弯强度(MPa:78.3±1.0,69.8±1.4,b 81.1±1 a) ,(B)弯曲模量(GPa:0.70±0.13,a 0.85±0.27,1.70±0.23 b),(C)努氏硬度(kg / cm 2:7.5±1.0,a 13.5±1.4,b 16.9±1.0 c )。不同的上标字母表示显着差异。所有Meliodent标本在弯曲测试过程中均断裂,但没有Deflex标本。结论:尽管聚酰胺义齿材料具有良好的抗断裂性,但其模量仍不足以与标准PMMA材料相当。临床意义。聚酰胺具有一些吸引人的优势,但需要进行改性以产生比当前PMMA材料更好的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号