Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 3: Preload and tensile fracture load testing.

机译:假体固定螺钉在体内长期使用后的力学行为和失效分析。第3部分:预紧力和拉伸断裂载荷测试。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: The aim of this study was to determine the preload and tensile fracture load values of prosthetic retaining screws after long-term use in vivo compared to unused screws (controls). Additionally, the investigation addressed whether the preload and fracture load values of prosthetic retaining screws reported by the manufacturer become altered after long-term use in vivo. MATERIALS AND METHODS: For preload testing, 10 new screws (controls) from Nobel Biocare (NB) and 73 used retaining screws [58 from NB and 15 from Sterngold (SG)] were subjected to preload testing. For tensile testing, eight controls from NB and 58 used retaining screws (46 from NB and 12 from SG) were subjected to tensile testing. Used screws for both tests were in service for 18-120 months. A custom load frame, load cell, and torque wrench setup were used for preload testing. All 83 prosthetic screws were torqued once to 10 Ncm, and the produced preload value was recorded (N) using an X-Y plotter. Tensile testing was performed on a universal testing machine and the resulting tensile fracture load value was recorded (N). Preload and tensile fracture load values were analyzed with 2-way ANOVA and Tukey post-hoc tests. RESULTS: There was a significant difference between preload values for screws from NB and screws from SG (p < 0.001). The preload values for gold alloy screws from NB decreased as the number of years in service increased. There was a significant difference between tensile fracture values for the three groups (gold alloy screws from NB and SG and palladium alloy screws from NB) at p < 0.001. The tensile fracture values for gold alloy screws from NB and SG decreased as the number of years in service increased. CONCLUSIONS: In fixed detachable hybrid prostheses, perhaps as a result of galling, the intended preload values of prosthetic retaining screws may decrease with increased in-service time. The reduction of the fracture load value may be related to the increase of in-service time; however, the actual determination of this relationship is not possible from this study alone.
机译:目的:本研究的目的是确定在体内长期使用后与未使用的螺钉(对照)相比,假体固定螺钉的预紧力和拉伸断裂载荷值。此外,研究还解决了制造商报告的在体内长期使用后假体固定螺钉的预紧力和断裂载荷值是否发生变化的问题。材料和方法:对于预紧力测试,对Nobel Biocare(NB)的10个新螺钉(对照)和73个旧固定螺钉[NB的58个和Sterngold(SG)的15个]进行了预紧力测试。对于拉伸测试,对NB的八个控件和58个使用的固定螺钉(NB的46个和SG的12个)进行了拉伸测试。两项测试中使用的螺丝已使用18-120个月。定制的载荷框架,载荷传感器和扭矩扳手设置用于预载荷测试。将所有83个修复螺钉拧紧一次至10 Ncm,并使用X-Y绘图仪记录产生的预紧值(N)。在通用试验机上进行拉伸试验,并记录所得的拉伸断裂载荷值(N)。通过2通ANOVA和Tukey事后检验分析了预紧和拉伸断裂荷载值。结果:NB螺钉和SG螺钉的预紧力值之间存在显着差异(p <0.001)。 NB的金合金螺丝的预紧力值随着使用年限的增加而降低。三组(NB和SG的金合金螺钉和NB的钯合金螺钉)的拉伸断裂值之间存在显着差异,p <0.001。 NB和SG制成的金合金螺钉的拉伸断裂值随着使用年限的增加而降低。结论:在固定的可拆卸混合假体中,可能是由于磨损造成的,假体固定螺钉的预期预紧值可能会随着使用时间的增加而降低。断裂载荷值的减小可能与服役时间的增加有关。但是,仅通过这项研究不可能真正确定这种关系。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号