Purpose: Difficulties in sterilizing impressions have led to chemical disinfection solutions as an alternative; however, some impression materials are more sensitive to humidity. For example, polyether impression materials are more hydrophilic. This study investigated the effect of three disinfecting methods on the dimensional stability of three polyether impression materials. Materials and Methods: Three polyether impression materials (P2, Impregum Penta Soft, and Impregum Penta) were submitted to the following treatments: spray disinfectant (Mikrozid Liquid), immersion in 2% glutaraldehyde solution (Super-On), immersion in 0.525% sodium hypochlorite solution for 10 minutes, and a control group (not disinfected). Each group included five samples. After treatment, dimensional change was evaluated according to ISO 4823. The data were analyzed by 2-way analysis of variance at alpha= 0.05. Results: The mean percentages of linear dimensional change of materials P2, Penta Soft, and Penta were -0.040%, 0.098%, and 0.100%, respectively. The dimensional change associated with different disinfectant agents mikrozid liquid, 2% glutaraldehyde, room air (control), and 0.525% sodium hypochlorite was 0.013%, 0.024%, 0.077%, and 0.096%, respectively. The interaction between the impression materials and the disinfectant treatment was not significant. The disinfectant agents can be classified in two groups as low- and high-effected. The control group did not significantly differ from either group. Conclusion: From the standpoint of dimensional change, the disinfectants tested for 10 minutes caused no significant linear dimensional change in the polyether impression materials, compared with the control group.
机译:目的:难于对印模进行消毒,导致使用化学消毒液作为替代方案;但是,某些压印材料对湿度更敏感。例如,聚醚印模材料更亲水。这项研究调查了三种消毒方法对三种聚醚印模材料尺寸稳定性的影响。材料和方法:将三种聚醚印模材料(P2,Pimpregum Penta Soft和Impregum Penta)进行以下处理:喷雾消毒剂(Mikrozid Liquid),浸入2%戊二醛溶液(Super-On),浸入0.525%的钠中次氯酸盐溶液10分钟,并设对照组(未消毒)。每组包括五个样品。处理后,根据ISO 4823评估尺寸变化。通过2方差分析(α= 0.05)对数据进行分析。结果:材料P2,Penta Soft和Penta的线性尺寸变化的平均百分比分别为-0.040%,0.098%和0.100%。与不同消毒剂米克罗齐德液体,2%戊二醛,室内空气(对照)和0.525%次氯酸钠有关的尺寸变化分别为0.013%,0.024%,0.077%和0.096%。印模材料与消毒剂处理之间的相互作用不显着。消毒剂可分为低效和高效两类。对照组与两组均无显着差异。结论:从尺寸变化的角度来看,与对照组相比,测试10分钟的消毒剂在聚醚印模材料中没有引起明显的线性尺寸变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号