Effect of the Number of Supporting Implants on Mandibular Photoelastic Models with Different Implant-Retained Overdenture Designs

机译:支持种植体数量对具有不同种植体固位覆盖义齿设计的下颌光弹性模型的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: The purpose of the study was to evaluate the effect of the number of supporting implants and different retentive mechanisms on load transfer characteristics of mandibular overdentures. Materials and Methods: Two photoelastic models of edentulous mandibles were fabricated having two and four cylindrical implants (Calcitek, 4 × 13 mm) embedded in the parasymphyseal area. Four attachment systems were evaluated: single anchor attachment (ERA), bar-clip, bar with distally placed ball attachments, and bar with distally placed extracoronal rigid attachments (Easy Slot). A 133 N vertical force was applied unilaterally to the central fossa of the right first molar. The resulting stresses of the models were observed and recorded photographically in the field of a circular polariscope. Results: The highest stresses were observed with the bar with distally placed extracoronal rigid attachment (Easy Slot) design, followed by bar-ball, bar, and the single anchor attachment (ERA) for both models. The lowest stress was observed with the single anchor attachment (ERA) design for both models. There were slight differences in stress values around implants in both models. Conclusions: For all tested attachments on both models, the stress was concentrated on the ipsilateral implant. The bar-clip system allowed the distribution of load to all supporting implants in both models. Although the highest stress level observed with all attachment systems was moderate, the bar-Easy Slot attachment showed the highest stresses. The lowest stress was observed with the single anchor attachment (ERA) design for both models. Varying the number of implants had no significant effect on stress values around supporting implants.
机译:目的:该研究的目的是评估支持植入物的数量和不同的保持机制对下颌覆盖义齿的负荷传递特性的影响。材料和方法:制作了两个无牙颌下颌的光弹性模型,其中两个和四个圆柱状植入物(Calcitek,4×13 mm)嵌入在副突旁区域。评估了四个附着系统:单锚附着(ERA),杆夹,带有远端放置的球附着物的棒和带有远端放置的冠状外刚性附着物的附着物(简易插槽)。 133 N垂直力单侧施加到右第一磨牙的中央窝。在圆偏光镜领域中观察并照相记录模型产生的应力。结果:在两个模型中,带有远端放置的冠外硬质固定(Easy Slot)设计的棒观察到最高应力,其次是棒球,棒和单锚附着(ERA)。对于两个模型,使用单锚固附件(ERA)设计观察到的应力最低。在两个模型中,植入物周围的应力值均存在细微差异。结论:对于两个模型上所有测试的附件,应力均集中在同侧植入物上。杆夹系统允许将载荷分配到两个模型中的所有支撑植入物。尽管在所有附件系统中观察到的最高应力水平是中等的,但“钢筋简易插槽”附件显示出最高应力。对于两个模型,使用单锚固附件(ERA)设计观察到的应力最低。植入物数量的变化对支撑植入物周围的应力值没有显着影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号