首页> 外文期刊>Journal of nuclear medicine technology >Limulus amebocyte lysate testing: adapting it for determination of bacterial endotoxin in 99mTc-labeled radiopharmaceuticals at a hospital radiopharmacy.
【24h】

Limulus amebocyte lysate testing: adapting it for determination of bacterial endotoxin in 99mTc-labeled radiopharmaceuticals at a hospital radiopharmacy.

机译:变形细胞溶解物测试:在医院放射药房进行调整,以测定99mTc标记的放射药中的细菌内毒素。

获取原文
获取原文并翻译 | 示例
           

摘要

In practice, Limulus amoebocyte lysate testing is not a method of choice for (99m)Tc-labeled radiopharmaceuticals because these radiopharmaceuticals exhibit interference. However, our study proves the hypothesis that the addition of calcium chloride can circumvent this problem. The addition of calcium chloride provides an enhanced biologic quality control testing option for the final formulation of (99m)Tc-labeled radiopharmaceuticals at the hospital radiopharmacy end.
机译:在实践中,Li(99m)Tc标记的放射性药物不是Li气变形细胞裂解物测试的选择方法,因为这些放射性药物表现出干扰。但是,我们的研究证明了以下假设:添加氯化钙可以避免这一问题。氯化钙的添加为医院放射药房末端(99m)Tc标记的放射药的最终配方提供了增强的生物质量控制测试选项。