In-pile electrochemical measurements were performed in order to investigate the effect of radiation on the electrochemical corrosion behaviour of AISI 304 and AISI 316 in PWR primary water (400 ppm B and 2 ppm Li) at 300 degrees C. The corrosion potential was continuously monitored during the whole irradiation period. Polarization resistance measurements and electrochemical impedance spectroscopy were performed at regular intervals. Polarization curves were recorded halfway through and at the end of each reactor cycle. All measurements were performed on both an in-flux and an out-of-flux 3-electrode electrochemical cell, each containing a platinum high-temperature reference electrode and an yttrium-stabilized zirconia (YSZ) reference electrode. The results show a small influence of radiation on the corrosion potential. However, the impedance data show a marked difference between in-flux and out-of-flux. The Nyquist diagram shows one semi-circle and one flattened semi-circle of which a branch leaps off indicating an R-(R//C)-(CPEHRW) type equivalent circuit. (c) 2006 Elsevier B.V. All rights reserved.
机译:为了研究辐射对300℃的PWR初级水(400 ppm B和2 ppm Li)中AISI 304和AISI 316电化学腐蚀行为的影响,进行了堆内电化学测量。连续监测腐蚀电位在整个照射期间。定期进行极化电阻测量和电化学阻抗谱。在每个反应器循环的中途和结束时记录极化曲线。所有的测量均在流入型和流出型3电极电化学电池上进行,每个电极均包含铂高温参比电极和钇稳定氧化锆(YSZ)参比电极。结果表明辐射对腐蚀电位的影响很小。但是,阻抗数据显示流入量和流出量之间的明显差异。奈奎斯特图显示了一个半圆和一个扁平的半圆,其中的一个分支跳了起来,表示为R-(R // C)-(CPEHRW)型等效电路。 (c)2006 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号