BACKGROUND: Generally, threaded root-form endosseous dental implants are thought to perform poorly in short lengths (i.e., < 10 mm). However, whether modifications in implant surface geometry will improve performance of short threaded implants is less clear. METHODS: The relationship between dental implant failure rates and their surface geometry, length, and location (maxilla versus mandible) was explored in the published literature. Using a MEDLINE search (1985 through 2001), studies were sought with the following criteria: 1) data suitable to calculate failure rates of implant lengths < or = 7 mm versus > 7 mm; 2) data separable into maxillary versus mandibular results; 3) criteria for "failure" clearly defined; and 4) minimal functional period of 2 years. RESULTS: Twelve papers were identified as follows: eight with machined threaded implants, two with acid-treated threaded implants, and two with sintered porous-surfaced press-fit implants. The following results were found: 1) machined surface implants experienced greater failure rates than textured surface implants; 2) with the exception of sintered porous-surfaced implants, 7 mm long dental implants appear to have higher failure rates than those > 7 mm length; and 3) with textured surface implants, higher failure rates were more likely in the maxilla than in the mandible, but with machined surface implants there were no differences in failure rates between maxilla and mandible. CONCLUSIONS: Dental implant surface geometry is a major determinant in how well these implants perform in short lengths, defined here as lengths of < or = 7 mm. While threaded implants show higher failure rates in short versus longer lengths, sintered porous-surfaced implants perform well in the defined "short" lengths. More studies are needed to better assess the performance of short, acid-washed threaded implants.
机译:背景:通常认为,牙根状齿状牙种植体在短长度(即<10 mm)内性能较差。但是,对植入物表面几何形状的修改是否会改善短螺纹植入物的性能尚不清楚。方法:在已发表的文献中探讨了种植牙失败率与其表面几何形状,长度和位置(上颌骨与下颌骨)之间的关系。使用MEDLINE搜索(1985年至2001年),以以下标准进行研究:1)适用于计算植入物长度<或= 7 mm对> 7 mm的失败率的数据; 2)数据可分为上颌和下颌结果; 3)明确定义“失败”标准;和4)最短运作期限为2年。结果:鉴定出十二篇论文,其中八篇采用机械加工螺纹植入物,两篇采用酸处理的螺纹植入物,另两篇采用烧结的多孔表面压入式植入物。发现以下结果:1)机械加工的表面植入物比起纹理的表面植入物经历更大的失败率; 2)除烧结多孔表面植入物外,长于7 mm的牙科植入物的故障率似乎高于长于7 mm的植入物。 3)对于有纹理的表面植入物,上颌骨的失败率比下颌骨更高,但机械加工的表面植入物在上颌骨和下颌骨之间的失败率没有差异。结论:牙种植体的表面几何形状是决定这些植入物在短长度下性能的主要决定因素,短长度在此定义为小于或等于7毫米的长度。虽然螺纹植入物在短长度和较长长度上显示出较高的失败率,但烧结的多孔表面植入物在定义的“短”长度上表现良好。需要更多的研究来更好地评估酸洗短螺纹植入物的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号