Background: Immediate loading of dental implants is currently one of the most examined topics in implant dentistry. Using screw implants with a microstructured surface and bone-quality-adapted insertion procedures, osseointegration is achieved when implants are initially stable and when splinted with the superstructure. Despite reported success, there is a shortage of information relating to remodeling and peri-implant bone formation with immediately loaded implants. Methods: Four to six immediately loaded and unloaded dental implants with a microstructured surface were placed in the mandible and the maxilla in seven minipigs. A total of 85 implants were placed. After a 4-month healing period, all implants were retrieved. Histomorphometry was performed using a light microscope in transmitted polarized light connected to a high-resolution video camera interfaced to a monitor and personal computer. This optical system was associated with a digitizing pad and a histomorphometry software package with imagecapturing capabilities. Results: Implants showed osseointegration if the average insertion torque of the implants within one bridge was >35 Ncm. If the primary stability of the bridge was <35 Ncm, all implants in the quadrant were lost after 4 months. The multivariate discriminant analysis showed the highest correlation for implant stability by bridge insertion torque (BIT), localization (mandible or maxilla), and implant insertion torque (IIT) as success parameters. The loaded implants displayed collagen fibers, which were oriented in a more transverse way. In addition, a higher quantity of secondary osteons was present. In comparison, the unloaded implants had collagen fibers with a more parallel orientation, and a higher quantity of marrow spaces was present. Conclusions: When observed after 4 months, immediately loaded implants showed a higher degree of bone formation and remodeling in comparison to unloaded implants. Immediately loaded implants also demonstrated a prevalence of transversely oriented collagen fibers in the peri-implant bone. In this animal model, an average insertion torque of the implants within one bridge >35 Ncm was associated with the most successful implants.
机译:背景:立即种植牙种植体是目前种植牙学中研究最多的主题之一。使用具有微结构表面的螺钉植入物和适应骨质量的插入程序,当植入物最初稳定并夹有上层结构时,即可实现骨整合。尽管取得了成功的报道,但缺少有关立即植入种植体的重塑和种植体周围骨形成的信息。方法:将四到六颗立即装卸的具有微结构表面的牙科植入物放入下颌骨和上颌骨中的七只迷你猪中。总共放置了85个植入物。在4个月的愈合期后,所有植入物均被取出。使用光学显微镜在透射偏振光中进行组织形态测定,该透射偏振光连接到与监视器和个人计算机相连的高分辨率摄像机。该光学系统与数字化板和具有图像捕获功能的组织形态测量软件包相关联。结果:如果植入物在一个桥内的平均插入扭矩大于35 Ncm,则植入物显示骨整合。如果桥的主要稳定性小于35 Ncm,则在4个月后该象限中的所有植入物都会丢失。多元判别分析通过桥插入扭矩(BIT),定位(下颌骨或上颌骨)和植入物插入扭矩(IIT)作为成功参数,显示出植入物稳定性的最高相关性。负载的植入物显示胶原纤维,其以更横向的方式取向。另外,存在大量次生骨。相比之下,空载植入物的胶原纤维取向更平行,并且存在更多的骨髓间隙。结论:4个月后观察,与未加载的植入物相比,立即加载的植入物显示出更高的骨形成和重塑程度。立即装载的植入物还显示出植入物周围骨中普遍存在横向取向的胶原纤维。在这种动物模型中,最成功的植入物与一个大于35 Ncm的桥内的植入物的平均插入扭矩有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号