The Cape Hatteras Lighthouse is the tallest brick structure of its kind in the United States. The national icon was closed to visitors after several pieces of the cast iron stairs, original to the structure, dislodged and fell inside the lighthouse. This finding led to the investigative efforts outlined in this paper, on the load carrying capacity of the stairs. This article summarizes the engineering effort in the condition assessment of the stairs, the review of visitor statistical data for likely load exposures during peak times, and the development of a unique load test program for the stairs of the historic structure. The load testing program was unique because of the physical constraints of the lighthouse shaft as well as the dimensions of the stair treads. In addition, the engineering team had the added objective of protecting the integrity of the national icon and performing the load test without exposing the historic stairs to an unnecessary risk of failure.
机译:哈特拉斯角灯塔是美国同类建筑中最高的砖结构。几个原始结构的铸铁楼梯移下并掉入灯塔后,国家标志对游客关闭。这一发现导致本文概述了有关楼梯的承载能力的调查工作。本文总结了楼梯状态评估中的工程设计工作,对高峰时段可能的负载暴露的访客统计数据的回顾,以及针对历史建筑的楼梯的独特负载测试程序的开发。负载测试程序之所以独特,是因为灯塔井道的物理限制以及楼梯踏板的尺寸。此外,工程团队的另一个目标是保护国家标志的完整性并执行负载测试,而又不会使历史悠久的楼梯暴露在不必要的故障风险之下。