Container closure integrity is a critical factor for maintaining product sterility and stability. Therefore, closure systems (found in vials, syringes, and cartridges) are designed to provide a seal between rubber stoppers and glass containers. To ensure that the contained product has maintained its sterility and stability at the time of deployment, the seal must remain intact within acceptable limits. To this end, a mathematical model has been developed to describe vacuum loss in evacuated drug vials. The model computes equivalent leak diameter corresponding to initial air leak rate as well as vacuum loss as a function of time and vial size. The theory accounts for three flow regimes that may be encountered. Initial leak rates from 10-8 to 103 sccm (standard cubic centimeters per minute) were investigated for vials ranging from 1 to 100mL. Corresponding leak diameters of 0.25-173μm were predicted. The time for a vial to lose half of its vacuum, the T50 value, ranged from many years at the lowest leak rates and largest vials, to fractions of a second at the highest leak rates and smallest vials. These results may be used to determine what level of initial vacuum leak is acceptable for a given product.
机译:容器密封的完整性是维持产品无菌性和稳定性的关键因素。因此,封闭系统(可在小瓶,注射器和药筒中找到)设计用于在橡胶塞和玻璃容器之间提供密封。为了确保所包含的产品在展开时保持其无菌性和稳定性,密封件必须在可接受的范围内保持完好无损。为此,已经开发出数学模型来描述抽空的药物瓶中的真空损失。该模型计算与初始空气泄漏率以及真空损失相对应的等效泄漏直径,该损失是时间和样品瓶尺寸的函数。该理论解释了可能遇到的三种流动状态。对于1至100mL的样品瓶,研究了10-8至103 sccm(标准立方厘米每分钟)的初始泄漏率。预计相应的泄漏直径为0.25-173μm。样品瓶失去其真空度一半的时间(T50值)的范围很长,从最低泄漏率和最大样品瓶的时间到几分之一秒(最高泄漏率和最小样品瓶)。这些结果可用于确定给定产品可接受的初始真空泄漏水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号