...
首页> 外文期刊>Journal of Pharmaceutical and Biomedical Analysis: An International Journal on All Drug-Related Topics in Pharmaceutical, Biomedical and Clinical Analysis >Determination of cortisol in human saliva by automated in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry.
【24h】

Determination of cortisol in human saliva by automated in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry.

机译:全自动管内固相微萃取-液相色谱-质谱联用测定人唾液中的皮质醇。

获取原文
获取原文并翻译 | 示例

摘要

We developed a simple, rapid, and sensitive method for determination of cortisol levels in human saliva. Cortisol was analyzed by on-line in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-mass spectrometry (LC/MS). Cortisol was separated within 5 min by HPLC using an Eclipse ZDB-C8 column and 1% acetic acid/methanol (50/50, v/v) at a flow rate of 0.2 mL/min. Electrospray ionization conditions in the positive ion mode were optimized for MS detection of cortisol. The optimum in-tube SPME conditions were 20 draw/eject cycles with a sample size of 40 microL using a Supel Q PLOT capillary column as the extraction device. The extracted compounds could be desorbed easily from the capillary by passage of the mobile phase, and no carryover was observed. Using the in-tube SPME LC/MS method, good linearity of the calibration curve (r=0.9977) was obtained in the concentration range 50-2000 pg/mL of cortisol in saliva, and the limit of detection (S/N=3) was 5 pg/mL. The method described here showed 48-fold higher sensitivity than the direct injection method (5 microL injection). The within-run and between-day precisions (relative standard deviations) were below 4.6% and 8.9% (n=5), respectively. This method was applied successfully to the analysis of saliva samples without interference peaks. The recoveries of cortisol spiked into saliva samples were above 95%, and the relative standard deviations were below 6.0%. This method was used to analyze the changes in salivary cortisol level according to stress load.
机译:我们开发了一种简单,快速且灵敏的方法来测定人唾液中的皮质醇水平。皮质醇通过在线管内固相微萃取(SPME)和液相色谱-质谱联用(LC / MS)进行分析。使用Eclipse ZDB-C8色谱柱和1%乙酸/甲醇(50/50,v / v),通过HPLC在5分钟内分离皮质醇,流速为0.2 mL / min。优化了正离子模式下的电喷雾电离条件,用于MS检测皮质醇。最佳的管内SPME条件是使用Supel Q PLOT毛细管柱作为提取装置的20抽/注循环,样品大小为40微升。萃取的化合物可通过流动相从毛细管中轻松解吸,并且未观察到残留。使用管内SPME LC / MS方法,在唾液中皮质醇的浓度范围为50-2000 pg / mL时,校准曲线具有良好的线性(r = 0.9977),并且检测限(S / N = 3) )为5 pg / mL。与直接进样法(5 microL进样)相比,此处描述的方法显示出48倍的灵敏度。批内和日间精度(相对标准偏差)分别低于4.6%和8.9%(n = 5)。该方法已成功应用于没有干扰峰的唾液样品分析。加标到唾液样品中的皮质醇的回收率高于95%,相对标准偏差低于6.0%。该方法用于分析唾液皮质醇水平根据压力负荷的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号