Microdialysis is a technique that allows continuous sampling of compounds from the interstitial fluid of different tissues with minimal influence on surrounding tissues and/or whole body function. In the present study, the feasibility of using microdialysis as a technique to sample free fatty acids (FFA) was investigated both in vitro and in vivo, by use of a high molecular weight (MW) cut-off membrane (3 MDa) and a push-pull system to avoid loss of perfusion fluid through the dialysis membrane. The relative recovery was examined in vitro for three different concentrations of radiolabelled oleic acid-BSA solutions (oleic acid:BSA molar ratio 1:1) and for various temperatures and flow rates. The recovery of oleic acid was found to be dependent on the concentration of analyte in the medium surrounding the membrane (17.3%, 29.0% and 30.6% for 50, 100 and 200 microM oleic acid-BSA solutions, respectively). Addition of 0.25% BSA to the perfusion fluid resulted, however, in a concentration-independent recovery of 31.4%, 28.1% and 28.1% for the 50, 100 and 200 microM solutions, respectively. The capability of the method to measure FFA together with glycerol was investigated in vivo in visceral adipose tissue of rats, before and after lipolytic treatment with the beta3-adrenergic agent, BRL37344. BRL37344 caused an increase in both dialysate FFA and glycerol, although the increase was markedly higher for glycerol, amounting to 24.5% and 329.2% increase from baseline, respectively. Subsequent in vitro test of probe performance revealed a decrease in the dialysing properties with regard to FFA, but not glycerol. This suggests that clogging of the membrane pores after 110 min prevented the measurement of the full FFA response in vivo.
机译:微透析是一种允许从不同组织的组织液中连续取样化合物的技术,而对周围组织和/或全身功能的影响最小。在本研究中,通过使用高分子量(MW)截留膜(3 MDa)和分离膜,在体外和体内研究了将微透析技术用作采样游离脂肪酸(FFA)的可行性。推挽系统可避免灌注液通过透析膜流失。在体外检查了三种不同浓度的放射性标记的油酸-BSA溶液(油酸:BSA摩尔比为1:1)以及各种温度和流速的相对回收率。发现油酸的回收率取决于膜周围介质中分析物的浓度(50、100和200 microM油酸-BSA溶液分别为17.3%,29.0%和30.6%)。但是,在灌注液中添加0.25%BSA会使50、100和200 microM溶液的浓度依赖性回收率分别为31.4%,28.1%和28.1%。在大鼠内脏脂肪组织中,在用β3-肾上腺素能药物BRL37344进行脂解处理之前和之后,研究了该方法测定甘油和FFA的能力。 BRL37344引起了透析液FFA和甘油的增加,尽管甘油的增加明显更高,分别比基线增加了24.5%和329.2%。随后的探针性能体外测试显示,相对于FFA,甘油的透析特性有所降低。这表明110分钟后膜孔的堵塞阻止了体内完整FFA应答的测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号