...
首页> 外文期刊>Clinical rehabilitation >Assessment of muscle strength and motor fatigue with a knee dynamometer in subjects with multiple sclerosis: a new fatigue index.
【24h】

Assessment of muscle strength and motor fatigue with a knee dynamometer in subjects with multiple sclerosis: a new fatigue index.

机译:用膝关节测力计评估多发性硬化患者的肌肉力量和运动疲劳:一种新的疲劳指数。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To measure muscle strength and motor fatigue with a knee dynamometer and to assess the intra-rater reliability of measurements for maximal isometric extensor and flexor torques and the reliability of a new fatigue index (FI) in patients with mild to moderate multiple sclerosis (MS). DESIGN: Repeated assessments with one-week intervals. SETTING: The Masku Neurological Rehabilitation Centre, Masku, and the Social Insurance Institution, Research Department, Turku, Finland. SUBJECTS: Twenty-eight MS patients. OUTCOME MEASURES: Maximal isometric torque during 5 s and fatigue of knee flexors and extensors during isometric contractions of 30 s were assessed. A new FI was established and compared with the two previously used indices (FI1 and FI2). All three indices are based on the calculated area under the force versus time curve (AUFC), with FI1 using the 30-s recording time in its entirety and F2 omitting the initial 5 s in the calculation. In the new fatigue index (FI3), the time point of maximum (TPM) torque achieved by the subject is used as the starting point in the calculation. The patient's subjective fatigue was measured by Fatigue Severity Scale (FSS). RESULTS: The intraclass correlation coefficient (ICC) was 0.97 in maximal isometric torque measurements. FI3 showed good intra-rater reliability (ICC =0.68-0.86). None of the fatigue indices correlated with FSS. CONCLUSIONS: Maximal isometric torque and motor fatigue of knee flexor and extensor muscles can be reliably measured using a knee dynamometer in MS patients. The new FI proved to be a reliable model for MS patients.
机译:目的:使用膝式测力计测量肌肉力量和运动疲劳,评估中度至中度多发性硬化症患者最大等长伸肌和屈肌扭矩测量值的评定内可靠性,以及新疲劳指数(FI)的可靠性(多发性硬化症)。设计:每隔一周进行一次重复评估。地点:Masku Masku神经康复中心和芬兰图尔库研究部社会保险机构。受试者:28名MS患者。观察指标:评估5 s内的最大等距扭矩以及30 s等距收缩期间膝盖屈伸肌的疲劳。建立了一个新的FI,并将其与先前使用的两个索引(FI1和FI2)进行比较。这三个指标均基于力与时间曲线(AUFC)下的计算面积,FI1整体使用30秒的记录时间,而F2则在计算中省略了最初的5 s。在新的疲劳指数(FI3)中,对象所达到的最大扭矩(TPM)的时间点将用作计算的起点。通过疲劳严重程度量表(FSS)测量患者的主观疲劳。结果:在最大等距扭矩测量中,组内相关系数(ICC)为0.97。 FI3显示出良好的评估者内部可靠性(ICC = 0.68-0.86)。没有疲劳指数与FSS相关。结论:使用膝部测力计可以可靠地测量MS患者的膝部屈肌和伸肌的最大等距扭矩和运动疲劳。新的FI被证明是MS患者的可靠模型。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号